Descriptions and drawings
29/82
2.4.7
X901 – Connector for NXHX-ENC, NXHX-IOL and standard MMIOs
MMIO pin header connector
X901
for the NXHX-ENC (part number
7924.000) and the NXHX-IOL module.
This connector can also be used as interface for standard MMIO, BiSS and
EnDat signals, and for connecting UART (NXHX-RS232 adapter module)
and CAN (NXHX-CO adapter module) peripherals to the application CPU of
the netX 90.
For identifying the connector on the board, see position
(7)
in section
Positions of interfaces and operating elements
X901
Pin
Signal
No netX
90
EnDat
BiSS
ADC
NXHX-IOL
NXHX-CO
NXHX-
RS232
1
MMIO1
ENDAT0_OUT BISS0_MO
–
IN_C/Q0
CAN0_APP_TX
CAN1_APP_TX
UART_APP
_TXD
2
MMIO0
ENDAT0_IN
BISS0_SL
-
OUT_C/Q1
CAN0_APP_RX
CAN1_APP_RX
UART_APP
_RXD
3
MMIO3
ENDAT0_CLK BISS0_MA
–
#EN_L+
–
UART_APP
_RTS#
4
MMIO2
ENDAT0_OE
BISS0_OE
-
ENC/Q0
-
UART_APP
_CTS#
5
GND
-
-
–
GND
GND
GND
6
+3V3
-
-
-
+3V3
+3V3
+3V3
7
MMIO5
-
-
ADC0-1
#IOLIRQ
PIO4
PIO4
8
MMIO4
-
-
ADC0-0
OUT_I/Q
or
*
#RSTOUT
PIO5
PIO5
9
MMIO7
-
-
ADC1-1
I2C_SCL
RSTOUT
RSTOUT
10
MMIO6
-
-
ADC1-0
I2C_SDA
-
-
*
To be configured by S1 switch on the NXHX-IOL module (see section
Table 21: Pin assignments X901
Note:
If you intend to use
EnDat
or
BiSS
signals, make sure to set all
switches of
S700
to OFF position. For identifying
S700
on the
board, see position
(13)
in section
·
For technical details of the
NXHX-ENC
module, see section
·
For technical details of the
NXHX-IOL
module, see section
·
For technical details of the
NXHX-RS232
module, see section
RS232 serial interface adapter
·
For technical details of the
NXHX-CO
module, see section
NXHX 90-JTAG | Device description
DOC170202HW03EN | Revision 3 | English | 2019-01 | Released | Public