CASE INSTALLATION
TRIM OUT
Drain and Pump Notes:
For the best energy conservation, Hillphoenix recommends
the use of
fl
oor drains at the store.
Con
fi
gurations exist (having ‘FD” at end of the case model
name) which restrict certain selections and tailor the case
for use with store
fl
oor drains. For “FD” con
fi
gured cases,
simply glue up the ship loose P-trap , cleanout, and Tee to
route condensate to the
fl
oor drain.
Other case con
fi
gurations (non-”FD”) allow ordering of
options (pumps and burn-off pans) that manage the conden-
sate for stores without
fl
oor drains. The following section
discusses the install of these condensate pumps and
burn-off pans.
Unpack pump, PVC drain trap, and 20 feet of plastic tubing.
Glue supplied PVC drain parts to the drain hub. Orient PVC
drain as needed to allow easy clean-out access for future:
typically clean-out to right side, with tube nipple facing left.
Place pump receptacle under case and ensure conduit /
wires are terminated to main junction box on case top.
Cut short section (18” typical) of tube. Connect from PVC
drain outlet nipple to pump inlet (choice of 4 removable
caps) Push tube toward short edge of pump
IMPORTANT
: If
tube pushed towards long end of pump it may interfere with
fl
oat that is located beneath motor. The RED ‘ALARM” light
will turn on if tube is holding
fl
oat up. If the tube holds
fl
oat
down, the motor will not engage to pump water. To correct,
pull out excess tube, and re-orient away from motor /
fl
oat.
Install long section of tube from pump outlet (nipple) and
route to top of case and into evaporative condensate pan.
PVC Drain Trap
Pump receptacle
Pump
Short tube section to pump inlet
Push towards short edge of pump.
Red “Alarm” light
Long tube section from pump
outlet nipple.
Pump Outlet Nipple
Assembled.
Summary of Contents for JNRBHSA
Page 2: ...ii ...
Page 33: ...B2 SEISMIC BRACKETS 5 BRACKETS ...
Page 34: ...C1 SPORLAN PRESSURE TEMPERATURE CHART ...
Page 38: ...Display Cases 5XIILQ 0LOO 5RDG RORQLDO HLJKWV 9 E3 ELECTRICAL WIRING DIAGRAM ...
Page 39: ...Display Cases 5XIILQ 0LOO 5RDG RORQLDO HLJKWV 9 E4 ELECTRICAL WIRING DIAGRAM ...
Page 46: ...G1 FASCIA FRAME ...
Page 47: ...G2 FASCIA FRAME ...
Page 48: ...G3 FASCIA FRAME ...
Page 49: ...G4 FASCIA FRAME ...
Page 50: ...G5 FASCIA FRAME OPTIONAL MOTION SENSOR INSTALLATION ...
Page 51: ...G6 FASCIA FRAME OPTIONAL MOTION SENSOR INSTALLATION ...
Page 53: ...G8 FASCIA FRAME JNRZHSA 5 BALLOON GUARD INSTALLATION ...
Page 55: ...I1 CASE LIFTING LOCATIONS Base Frame Lifting Locations for Forklift JNRBHSA JNRZHSA ...
Page 56: ...I2 CASE LIFTING LOCATIONS Base Frame Lifting Locations for Forklift JNRBHSA JNRZHSA ...
Page 57: ...v Ϯ Z Ͳ ϱ Z EZ v Ϯ Z Ͳ ϰ Z EZ v ϱ EZ J1 CONDENSING UNIT LOCATIONS ...