To set the pressure, rotate the control knob clockwise to
increase the fill pressure required. When you reach the
desired pressure, press the control knob to confirm.
The maximum pressure that can be set is 300BAR
(4350PSI/30MPa).
DO NOT SET THE COMPRESSOR ABOVE THE MANUFACTURER’S
RECOMMENDED PRESSURE FOR THE
BOTTLE
YOU ARE FILLING
.
As a safety feature t
he
target
pressure is not retained and will require resetting each time.
Rotate the control knob to reach the start display
Press the control knob and the compressor will commence filling
.
The display will show the operating temperature, the current
working pressure and the target set pressure
.
You can manually pause the filling at any time by pressing the
rotary control knob once, the display will show “Fill Abort?”
You can either confirm the fill abort by depressing the control
knob once more or to resume the fill,
rotate the control knob once more to show “Fill
R
esume”
and then press the knob to confirm
.
The compressor is programmed to only operate within a pre-set
temperature range. The compressor will automatically pause if
the working temperature exceeds this pre-set.
This is normal
and no operator intervention is required
. The display will show
the progress of the cooling cycle and when the working
temperature falls below the pre-set the compressor will restart. If you are filling a larger
b
ottle
, this could happen multiple times. You can abort the fill at any time within the cooling
cycle if required
.
DO NOT
disconnect the
bottle
until the compressor has been depressurised
.
Depressurise by
unscrewing
the bleed screw. Whilst
depressurising, the compressor
may
expel some moisture and
silicone from the moisture trap.
Suitable precautions should be
taken to protect any floor coverings under the compressor
.
When the target pressure is reached the display will show
“Fill complete” along with confirmation of the
achieved
pressure
and the target pressure.
7