External control (COMMAND) interface: control switch connects normally open switch.
5.4.4
Dip switch settings:
6. Set process
6.1
Learning and erasing transmitters: Press the learning button S3 in the board, LED DL2 is on,
enters into the learning process; Press the same button twice, LED blinks for several times, then off.
The learning process is successful. Press the learning button, continue pressing for 8s until LED
turns off; Release learning button, LED will be on (about 1s) and then off; the erasing process is
successful. (Ignore this step if transmitter already matches the opener before delivery).The board
can learn 30pcs transmitters max.
Tip of Remote control self-learning function: Use the transmitter that already has been learned as
old transmitter, press button 1 and button 2 at the same time and then press button 2 to let it enters
into the learning process .In this way , new transmitter can be learned without press the learning
button on the control board.
6.2
Opening/closing limit adjustment: Remote control the door ( or move the door manually ) , adjust
the position of limit device to make sure the door would touch the limit switch when open or close the
door .LED LD6/DL5 in the controller will be off when limit device touches limit switch(Limit switch is
NC).
6.3
Resistance adjustment: Adjust potentiometer P.Open/P.Close to change the opening/closing
resistance. Resistance increases when adjust it C.W .Make a resistance to door after the adjustment
in order to check if it is appropriate .
6.4
Motor quick running time setting: Adjust PT3 to change the quick running time(3-120S
adjustable), time increase when clockwise to adjust, time reduce when anticlockwise to adjust. Max
motor running time=quick running time +slow running time=127S. Motor quick running speed is
about 1/5M/S, slow running speed is about 1/17M/S.
6.5
External infrared switch: Photocell connector connects the NC contact of photocell switch , DL4
LED turn on after the connection, And DL4 LED turn off when blocking out the transmit or receive
signal of photocell artificially. Infrared sensor doesn't react when door opening and the door will
reverse to limit point if photocell signal disconnect when door closing. If no need of using photocell
protection, make the connector of photocell short circuit with terminated line(the connector is short
DIP2:
ON
:
Single button control
OFF
:
Three button control
DIP1:
ON
:
External limit NC switch
OFF
:
External limit NO switch
DIP3:Right/left installation
ON
:
In left side
OFF
:
In right side
DIP7 DIP8: Auto close time
OFF OFF
:
No Auto close
OFF ON
:
5S
ON OFF
:
10S
ON ON
:
30S
DIP5 DIP6 : function cancelled
DIP4 Latch and non-latch
ON
:
Deadman,latch
OFF
:
Non-latch