Thermal & Optical Bi-spectrum Network Camera User Manual
19
need to be uploaded to surveillance center, check Background Upload.
Text Overlay
You can check desired items (Device No., Camera Info. and Capture Time) and adjust their order
to display on captured pictures by
.
The content of Device No. and Camera Info should be input on the same page.
Set Shield Region
The shield region allows you to set the specific region in which the set smart function rule is
invalid.
Steps
1. Select Shield Region.
2. Click
to draw shield area. Repeat this step above to set more shield regions.
3. Optional: Click
to delete the drawn areas.
4. Click Save.
Face Capture Advanced Settings
It is used to set and optimize the parameters of the algorithm library for face capture.
Go to Configuration → Face Capture → Advanced Configuration.
Face Capture Version
It refers to the current algorithm version, which cannot be edited.
Detection Parameters
Generation Speed
The speed to identify a target. The higher the value is, the faster the target will be recognized.
The default value is recommended.
Sensitivity
The sensitivity to identify a target. The higher the value is, the easier a face will be detected, and
the higher possibility of misinformation would be. The default value of 3 is recommended.
Capture Parameters
Upload Feature
Feature stands for the feature information the algorithm can tell from face pictures. For
example, gender, facial expression, wearing glasses or not, etc. Check the function to upload the
information.
Best Shot
The device captures the target picture with the highest score after setting the parameters.