HIKVISION iDS-2XM6810F-I/C Configuration & Installation Manual Download Page 18

 

 

7)

 

Daily Reset Time: To reset the counter, you can set up a daily reset time. Or you can reset 
the counter manually by click Manual Reset. 

 

8)

 

Clear Storage Data: To clear stored data on camera, you can click the Clear button. Always 
do the operation with caution. Deleted data cannot be restored. 

 

3.2 Configuration Instruction 

3.2.1. Entry/Exit Area Configuration 

1) 

Keep the door open. 

2) 

Generally  Entry/Exit  Area  is  set  as  the  first  step  and  the  boundary  between  the  first  and 

second steps must be specific. 
3) 

The  size  of  Entry/Exit  Area  shouldn’t  be  set  too  large  or  small,  which  may  cover  the 

redundant area outside the step or cover incompletely. 

 

Summary of Contents for iDS-2XM6810F-I/C

Page 1: ...Configuration Installation Guidance of Mobile Dual lens People Counting Camera...

Page 2: ...ower On 10 Chapter 3 Configuration 11 3 1 Configuration Step 11 3 1 1 Image Configuration 11 3 1 2 Alarm Input Configuration 11 3 1 3 485 Configuration It is needed only when DVR is used 12 3 1 4 Peop...

Page 3: ...achieve high precision people counting It greatly improves the statistical accuracy rate and optimizes the adaptive capacity of camera which includes anti vibration capability radiation protection ca...

Page 4: ...m ordinary cameras Please read this chapter carefully before installation and the below are some key points should be considered Patch cord should be ordered in advance Proper installation position sh...

Page 5: ...ion proof silicone pad Hexagonal screwdriver and screws Include 4 expansion screws and self tapping screws Mounting Template Device patch cord Ordered separately SAP code 101505587 68 mobile dual lens...

Page 6: ...loss of accuracy What is Entry Exit Area for bus it s near the door where standing is forbidden region of the first step usually for coach it s the combined region of the first step and the second st...

Page 7: ...table of Lens Height Maximum Detection Width is shown as below Lens Height m Maximum Detection Width m 2 1 0 9 2 2 1 1 2 3 1 3 2 4 1 5 2 5 1 8 2 6 2 0 2 7 2 2 2 8 2 4 2 9 2 7 3 0 2 9 The Correspondin...

Page 8: ...side the ground The installation and the live view pictures are shown as below Installation position for bus 2 3 3 Coach Solution For coach it has some steps and the first step isn t suitable to be se...

Page 9: ...and Wiring Step 2 4 1 Installation Step Choose proper installation position and mount the camera according the following steps 1 Remove the housing by the hexagonal screwdriver 2 Thread cable through...

Page 10: ...ry parameter of algorithm the connection configuration is different according to the type of the signal Level Signal or Pulse Signal Level Signal a Level Signal transfers on two wire cord which will b...

Page 11: ...gh but not overexposure 2 Make sure device time is correct and then disable OSD 3 1 2 Alarm Input Configuration Alarm input configuration is needed and the configuration method is different according...

Page 12: ...save the configuration 3 Set Alarm Input No as A 2 If the alarm is triggered by high pulse set Alarm Type as NO if triggered by low pulse set Alarm Type as NC Then save the configuration 3 1 3 485 Con...

Page 13: ...Exit area to the camera and click Calibrate then a red frame and a yellow line will automatically appear in the image The red frame is for counting and the yellow line is for detection Make sure the r...

Page 14: ...ea Confirm the nodes which the supported maximum number is 10 by left mouse button and click right mouse button to confirm the drawn area 6 Save it after finishing the configuration Set the Arming sch...

Page 15: ...will keep counting all the time and will influence the accuracy rate RS 485 data transmission isn t supported under this mode b Triggerd by Alarm Input It controls the open closed status via accessing...

Page 16: ...ormation in the live view image Enter Leave Enter Leave and None are optional 3 Display Rule Info on Stream It will display the ID number and height information of tracking people after enabling it Th...

Page 17: ...tus of the camera There are three types optional Counting Stop counting Pause counting You can click Refresh button to refresh the status Counting Count normally Stop counting Disable people counting...

Page 18: ...Always do the operation with caution Deleted data cannot be restored 3 2 Configuration Instruction 3 2 1 Entry Exit Area Configuration 1 Keep the door open 2 Generally Entry Exit Area is set as the fi...

Page 19: ...the counting area 4 The direction must point to the inside of vehicle 3 3 Statistics Results 1 Enter Application People Counting 2 Choose a Report Type Daily Weekly Monthly Annual Report are selectabl...

Page 20: ...rules and configuration information during the debugging process 4 1 Screenshot of Configuration Save the screenshot of Basic Information Alarm input and Rule of people counting 4 2 Internal Paramete...

Page 21: ...2 Click Product Related BV Correct...

Page 22: ...4 3 Get Dual lens Video 1 Access the camera via web browser 2 Enter Configuration Video Audio Video 3 Set stream type as Sub Stream and modify the Max Bitrate to 8012Kbps then save it...

Page 23: ...witch the stream type to Sub Stream in the live view interface The image will be displayed as a montage image which includes the upper and lower image Click Start Recording button to record then save...

Reviews: