background image

 

Network Positioning System

·

Quick Start Guide

 

 

21

8

37

7.

5

188

396

IR

Shield

Wiper

Main Body

Base

Unit: mm

 

Figure 1-6

 

Dimensions of DY7xxx Series IR Network Positioning System (Type I with 

Wiper) 

Unit: mm

396

188

37

7.

5

21

8

Shield

Main Body

Base

 

Figure 1-7

 

Dimensions of DY7xxx Series Network Positioning System (Type II) 

Summary of Contents for DY5 Series

Page 1: ...Network Positioning System Quick Start Guide...

Page 2: ...ind the latest version in the company website http overseas hikvision com en Please use this user manual under the guidance of professionals Trademarks Acknowledgement and other Hikvision s trademarks...

Page 3: ...DE TIMELY TECHNICAL SUPPORT IF REQUIRED SURVEILLANCE LAWS VARY BY JURISDICTION PLEASE CHECK ALL RELEVANT LAWS IN YOUR JURISDICTION BEFORE USING THIS PRODUCT IN ORDER TO ENSURE THAT YOUR USE CONFORMS T...

Page 4: ...ence 2 This device must accept any interference received including interference that may cause undesired operation EU Conformity Statement This product and if applicable the supplied accessories too a...

Page 5: ...local codes Install blackouts equipment into the power supply circuit for convenient supply interruption If the product does not work properly contact your dealer or the nearest service center Never...

Page 6: ...a proper operating environment While shipping the product should be packed in its original packing Use the provided glove when open up the product cover Do not touch the product cover with fingers di...

Page 7: ...ning System Type II 18 2 1 3 Installing DY9xxx Series Network Positioning System Type I 21 2 2 Installing DY7xxx Network Positioning System 21 2 3 Installing DY5xxx Network Positioning System 21 3 Set...

Page 8: ...Series DY9xxx Series 1 1 1 Overview of DY5xxx Series Network Positioning System Shield Auxiliary Light Side Shield Camera Side Wiper Main Body Base 306 212 165 Unit mm Figure 1 1 Dimensions of DY5xxx...

Page 9: ...f DY5xxx Series Mobile Network Positioning System Type II Unit mm 134 4 9 140 140 175 175 Figure 1 4 Dimensions of Shock absorbing Pad for DY5xxx Series Mobile Network Positioning System Type II 1 1 2...

Page 10: ...188 396 IR Shield Wiper Main Body Base Unit mm Figure 1 6 Dimensions of DY7xxx Series IR Network Positioning System Type I with Wiper Unit mm 396 188 377 5 218 Shield Main Body Base Figure 1 7 Dimens...

Page 11: ...Main Body Base Figure 1 8 Dimensions of DY9xxx Series Network Positioning System Type I Unit mm 460 180 491 Wiper Shield Main Body Base IR Module Figure 1 9 Dimensions of DY9xxx Series IR Network Pos...

Page 12: ...Figure 1 12 Bottom View of DY9xxx Series Network Positioning System 1 2 Cable Descriptions Cables of network positioning system are shown in Figure 1 13 The cables are distinguished by different colo...

Page 13: ...hen it connects to the alarm device JQC 3FG Relay 30VDC GND OUT L N 220V AC Relay Output 10A 250VAC Diagram left Diagram right 1A OUT n OUT n DC DC Load Relay Output Positioning System OUT n OUT n Pos...

Page 14: ...aring and stability of the upholder It s highly recommended to install the system to the upholder directly If you need to install the positioning system to the bracket refer to bottom view of the posi...

Page 15: ...supplementary lighting system will adjust the light according to the zoom ratio and then you can see the laser spot on the live view image If the spot location is the same as shown in figure A you can...

Page 16: ...2 4 Open the Lid of Housing Type III For type IV camera loosen the screws of sunshield and top cover Take down the sunshield and top cover M4 Cross Screw Sunshield Top Cover M4 Torx Needle Screw Figur...

Page 17: ...mory Card Type III Memory Card Memory Card DarkFighterX Figure 2 7 Insert the Memory Card Type IV 4 Slightly adjust the control screws for the laser according to the actual situation Tilting Adjustmen...

Page 18: ...the two panning fastening screws rotate the eccentric wheel to adjust the laser spot in the horizontal direction and fasten the screws after adjusting Tilt Adjustment Tighten or loosen the tilting adj...

Page 19: ...oning System Type II Steps 1 Install the IR module 1 Align the screw holes on the IR bracket with the screw holes on the housing as shown in Figure 2 12 Insert and tighten the two M4 10 screws to secu...

Page 20: ...o IR Bracket 2 Route the cables of IR modules 1 Pull out the two original plugs from the housing 2 Loosen the nuts on the water proof cable plugs 3 Route the IR module cables through the cable holes o...

Page 21: ...ide of the housing and pull the bolts outward from the housing 2 Open the lid Figure 2 16 Open the Housing 3 Connect the cables to the connectors on the housing respectively Figure 2 17 Connect the Ca...

Page 22: ...DY9xxx Series IR Network Positioning System Type II Refer to section 2 1 2 Installing DY9xxx Series IR Network Positioning System Type II 2 2 Installing DY7xxx Network Positioning System There are tw...

Page 23: ...you need such service 3 1 Wiring To view and configure the network positioning system via LAN Local Area Network you need to connect the positioning system in the same subnet with your PC Then install...

Page 24: ...he default IP address of the positioning system is 192 168 1 64 The computer and the positioning system should belong to the same subnet For the positioning system enables the DHCP by default you need...

Page 25: ...em in batch Refer to the user manual of SADP software for details 3 Create a password and input the password in the password field and confirm the password STRONG PASSWORD RECOMMENDED We highly recomm...

Page 26: ...ubnet with your PC Then install the SADP software or client software to search and change the IP address of network positioning system We will take modifying the IP address via SADP software as an exa...

Page 27: ...fer to section 5 1 Enable Hik Connect Service on Positioning System Hik Connect service is not supported by certain positioning system models 4 Input the admin password and click Modify to activate yo...

Page 28: ...g system and enter the login interface Note The default IP address is 192 168 1 64 You are recommended to change the IP address to the same subnet with your computer 3 Input the user name and password...

Page 29: ...8 Figure 4 2 Download Plug in 6 Reopen the web browser after the installation of the plug in and repeat above step 2 to step 4 to login Note For detailed instructions of further configuration refer to...

Page 30: ...tioning system before using the service You can enable the service through SADP software or web browser 5 1 1 Enable Hik Connect Service via SADP Software Steps 1 Check the Enable Hik Connect checkbox...

Page 31: ...uration Network Advanced Settings Platform Access Figure 5 2 Platform Access Configuration Web 3 Select Platform Access Mode as Hik Connect 4 Check the Enable checkbox 5 Click and read Terms of Servic...

Page 32: ...ng system via optical interface 2 In the Hik Connect app tap on the upper right corner and then scan the QR code of the positioning system to add the positioning system You can find the QR code on the...

Page 33: ...fer to the user manual of the Hik Connect app 5 4 Initializing the Memory Card Check the memory card status by tapping on the Storage Status in the Device Settings interface If the memory card status...

Page 34: ...UD10187B...