Auxiliary Care Radar • User Manual
6
The parameter “00-2.10;” in algorithm parameters means that the distance from the radar to the
bed is 2.1 m. Edit the value according to the actual using environment.
Parameter Settings
Click
and click Read after SoftVersion to read the software version.
Click
, set the address code, and click Set to edit the sub-device address.
The address code range is 1 to 255. Make sure the device connected address is the sub-device
address or 0.
Click
, select Report form mode, and click Set.
Start reporting
The radar will upload detection data for every 50 ms. This mode is for single radar debugging,
and you do not need to search for every time.
Stop reporting