Hang on the wire with soft metal
⑨
Warning
signs
The warning sign of “High Voltage No Climbing” should be installed every 10 meters on the top
line of high conductivity wire and fixed on with soft metals. Remember to fix the three holes on the
warning sign in case that it sways in the wind.
Fix on post
with
soft
metal
⑩
Energizer
1.
Energizer
outside
should
be
installed
in
the
waterproof
box
that
is
mounted
under
the
fence
or
at
the
partitions
of
the
fence
(calibrated
in
the
drawings).
There
requires
a
40
cm
interval
between
fence
and
waterproof
box
that
can
be
fixes
on
the
wall
with
concrete
anchors,
as
is
shown
in
fig:
Fix waterproof
box with
expansion
screws at the
back.
2. Make sure the energizer, waterproof box and
earthing pile
are well connected.
The grounding of energizer (weak voltage grounding, connect with the shielding layer of
communication wire) and high-voltage fences should be apart from each other to avoid
interference.
3. The high-voltage lead of energizer should be connected with front end fences
through PVC
conduit and the joints can be reliably connected with a wire connector (or self winding).
4.
A
larm output line and power line should be separated from the
high-voltage
line and use a separate conduit.