HIKVISION DS-K5032 Series User Manual Download Page 7

• Do not connect several devices to one power adapter as adapter overload may cause over-heat

or fire hazard.

• Please make sure that the power has been disconnected before you wire, install or dismantle the

device.

• If smoke, odors or noise rise from the device, turn off the power at once and unplug the power

cable, and then please contact the service center.

• If the product does not work properly, please contact your dealer or the nearest service center.

Never attempt to disassemble the device yourself. (We shall not assume any responsibility for

problems caused by unauthorized repair or maintenance.)

 Cautions:

• No naked flame sources, such as lighted candles, should be placed on the equipment.

• The ventilation should not be impeded by covering the ventilation openings with items, such as

newspapers, table-cloths, curtains, etc. The openings shall never be blocked by placing the

equipment on a bed, sofa, rug or other similar surface.

• The serial port of the equipment is used for debugging only.

• Do not drop the device or subject it to physical shock, and do not expose it to high

electromagnetism radiation. Avoid the equipment installation on vibrations surface or places

subject to shock (ignorance can cause equipment damage).

• Do not place the device in extremely hot (refer to the specification of the device for the detailed

operating temperature), cold, dusty or damp locations, and do not expose it to high

electromagnetic radiation.

• The device cover for indoor use shall be kept from rain and moisture.

• Exposing the equipment to direct sun light, low ventilation or heat source such as heater or

radiator is forbidden (ignorance can cause fire danger).

• Do not aim the device at the sun or extra bright places. A blooming or smear may occur

otherwise (which is not a malfunction however), and affecting the endurance of sensor at the

same time.

• Please use the provided glove when open up the device cover, avoid direct contact with the

device cover, because the acidic sweat of the fingers may erode the surface coating of the device

cover.

• Please use a soft and dry cloth when clean inside and outside surfaces of the device cover, do

not use alkaline detergents.

• Please keep all wrappers after unpack them for future use. In case of any failure occurred, you

need to return the device to the factory with the original wrapper. Transportation without the

original wrapper may result in damage on the device and lead to additional costs.

• Improper use or replacement of the battery may result in hazard of explosion. Replace with the

same or equivalent type only. Dispose of used batteries according to the instructions provided by

the battery manufacturer.

• Biometric recognition products are not 100% applicable to anti-spoofing environments. If you

require a higher security level, use multiple authentication modes.

DS-K5032 Series Visitor Terminal User Manual

vi

Summary of Contents for DS-K5032 Series

Page 1: ...DS K5032 Series Visitor Terminal User Manual...

Page 2: ...L HIKVISION BE LIABLE TO YOU FOR ANY SPECIAL CONSEQUENTIAL INCIDENTAL OR INDIRECT DAMAGES INCLUDING AMONG OTHERS DAMAGES FOR LOSS OF BUSINESS PROFITS BUSINESS INTERRUPTION OR LOSS OF DATA CORRUPTION O...

Page 3: ...device with facial recognition features biometrics data is stored in your device with encryption method for fingerprint device only fingerprint template will be saved which is impossible to reconstru...

Page 4: ...can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Inc...

Page 5: ...to indicate cadmium Cd lead Pb or mercury Hg For proper recycling return the battery to your supplier or to a designated collection point For more information see www recyclethis info This device com...

Page 6: ...If the battery compartment does not close securely stop using the product and keep it away from children 5 If you think batteries might have been swallowed or placed inside any part of the body seek...

Page 7: ...erating temperature cold dusty or damp locations and do not expose it to high electromagnetic radiation The device cover for indoor use shall be kept from rain and moisture Exposing the equipment to d...

Page 8: ...Available Model Product Name Model Visitor Terminal DS K5032 DS K5032 Series Visitor Terminal User Manual vii...

Page 9: ...1 2 Connect to HikCentral Professional Optional 7 5 2 Login 9 5 3 Self Service Visitor Terminal VS Staff Service Visitor Terminal 10 5 3 1 Staff Service Visitor Terminal 11 5 3 2 Self Service Visitor...

Page 10: ...puses factories etc 1 2 Main Features Android operation system with single or dual screen design Supports staff sevice and self service mode Paperless visitor enrollment Supports both stand alone and...

Page 11: ...of Face Recognition Terminal No Description 1 Power Switch Hold Power On Power Off Reboot Press Sleep Wake Up 2 Visitor Screen Note The models which contains only one screen do not support the visitor...

Page 12: ...Supports the USB import function You can use the interface to upload the event to the client software etc 12 Reserved 13 Reserved 14 Power Interface 15 Network Interface 16 Reserved 17 USB 2 0 Note T...

Page 13: ...ronment see Tips for Installation Environment 3 2 Installation Steps 1 Put the device on the surface Note This equipment is suitable for mounting on concrete or other non combustible surface only 2 Pl...

Page 14: ...Chapter 4 Wiring The suggested wiring diagram is as follows Figure 4 1 Wiring Diagram DS K5032 Series Visitor Terminal User Manual 5...

Page 15: ...reate Administrator Account For the first time login you should create an administrator account first before you can do further operations Steps Note The password of the account can be used for author...

Page 16: ...inal to the HikCentral Professional system After that the visitor terminal and the HikCentral Professional system will be able to transmit data with each other This allows you to use more functions to...

Page 17: ...ion can be set during visitor registration Setting Extended Open Duration is not supported After you create the administrator account a window will pop up to remind you to configure network You can ta...

Page 18: ...the HikCentral Professional system Note For details about connecting the vistior terminal to the HikCentral Professional system see Connect to HikCentral Professional Optional If you want to log in t...

Page 19: ...ion personnel displays the operation interface Roles of Visitor and Staff The visitor is the operator who can do most of the operations by herself himself While the reception personnel is the guider w...

Page 20: ...ou can tap Skip at the upper right corner of the page to skip person and ID comparison It is recommended that you do person and ID comparison to prevent identity theft Based on the visitor terminal se...

Page 21: ...al Professional Web Client User Manual Extended Open Duration The time interval between the door is unlocked and locked again for the person whose extended access function enabled Note The parameter i...

Page 22: ...elf Only the reception personnel and similar staff can check out the visitors You can tap in the Operation column of the visitor list to manually check out a visitor or select a visitor form the visit...

Page 23: ...st to view the visitor details If the visitor has been checked out you can tap Register Again on the visitor details page to register her him again if required Note For details about visitor registrat...

Page 24: ...on personnel or other similar staffs Steps Note You in the steps below refers to the visitor 1 Open your passport and then place it onto the scanning area to allow the visitor terminal to capture a pi...

Page 25: ...it to check out by herself himself And if a visitor hasn t checked out until the latest check out time he she will be checked out automatically Steps Note The visitor can set the latest check out time...

Page 26: ...e on the scanned ID e g passport In this way using fake ID for registration will be prevented Person and ID Comparison Threshold Set the threshold 0 to 100 of similarity level for determining that the...

Page 27: ...surface temperature that is considered normal If the skin surface temperature of a visitor is lower than the threshold temperature alarm will be triggered the abnormal temperature will be highlighted...

Page 28: ...l Professional system Network Settings Wired Network View the details of the connected wired network such as the IP address of the wired network Wi Fi View available Wi Fi addresses and connect the vi...

Page 29: ...d and displayed on visitor terminal Visitor Records Retention Period Set the retention period for the registered visitor information The visitor information will be deleted automatically when the rete...

Page 30: ...sion in the picture below Do not wear hat sunglasses or other accessories that can affect the facial recognition function Do not make your hair cover your eyes ears etc and heavy makeup is not allowed...

Page 31: ...DS K5032 Series Visitor Terminal User Manual 22...

Page 32: ...ference Value Candle 10Lux Bulb 100 850Lux Sunlight More than 1200Lux 2 Install the device at least 2 meters away from the light and at least 3 meters away from the window or door 3 Avoid backlight di...

Page 33: ...Appendix C Dimension DS K5032 Series Visitor Terminal User Manual 24...

Page 34: ...Hikvision access control and video intercom devices Figure D 1 QR Code of Communication Matrix Device Command Scan the following QR code to get the device common serial port commands Note that the co...

Page 35: ...UD20585B...

Reviews: