Chapter 3 Installation

3.1 Disassemble Pedestals

Before installation, you should use the key to open the pedestals.
View the pictures below to find the lock holes.

Figure 3-1 Lock Holes

Note

Please check and avoid metal pieces dropped into the high and low voltage modules, which will

cause short circuit.

DS-K3Y411X Series Flap Barrier Quick Start Guide

6

Summary of Contents for DS-K3Y411 Series

Page 1: ...DS K3Y411X Series Flap Barrier Quick Start Guide...

Page 2: ...HIKVISION BE LIABLE TO YOU FOR ANY SPECIAL CONSEQUENTIAL INCIDENTAL OR INDIRECT DAMAGES INCLUDING AMONG OTHERS DAMAGES FOR LOSS OF BUSINESS PROFITS BUSINESS INTERRUPTION OR LOSS OF DATA CORRUPTION OF...

Page 3: ...evice with facial recognition features biometrics data is stored in your device with encryption method for fingerprint device only fingerprint template will be saved which is impossible to reconstruct...

Page 4: ...an be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Incre...

Page 5: ...lection points For more information see www recyclethis info 2006 66 EC battery directive This product contains a battery that cannot be disposed of as unsorted municipal waste in the European Union S...

Page 6: ...wer source during servicing Keep body parts away from motors Disconnect the power source during servicing To prevent possible hearing damage do not listen at high volume levels for long periods All th...

Page 7: ...combustible surface only Install the equipment according to the instructions in this manual To prevent injury this equipment must be securely attached to the floor wall in accordance with the installa...

Page 8: ...tructions provided by the battery manufacturer Biometric recognition products are not 100 applicable to anti spoofing environments If you require a higher security level use multiple authentication mo...

Page 9: ...K3Y411X L2 Dp60 DS K3Y411X L2 Dp60 S12 DS K3Y411X M1 Middle Pedestal 1 DS K3Y411X M1 M Dp60 DS K3Y411X M1 M Dp60 S12 DS K3Y411X M2 Middle Pedestal 2 DS K3Y411X M2 M Dp60 DS K3Y411X M2 M Dp60 S12 DS K3...

Page 10: ...Scan the QR code to get User Manual of Flap Barrier Note that mobile data charges may apply if Wi Fi is unavailable DS K3Y411X Series Flap Barrier Quick Start Guide ix...

Page 11: ...onal 14 4 5 Terminal Description 14 4 5 1 UART Related Terminal and Position 14 4 5 2 Main Control Board Terminal Description 17 4 5 3 Sub Control Board Terminal Description 18 4 5 4 BUS Terminal Desc...

Page 12: ...n 42 6 1 Activate via SADP 42 6 2 Activate Device via Client Software 43 Appendix A DIP Switch Description 45 Appendix B Event and Alarm Type 46 Appendix C Table of Audio Index Related Content 47 Appe...

Page 13: ...eve the concern of privacy leak Permissions validation and anti tailgating Remaining open closed mode selectable Bidirectional Entering Exiting lane The barrier opening and closing speed can be config...

Page 14: ...When the fire alarm is triggered the barrier will be open automatically for emergency evacuation Valid passing duration settings System will cancel the passing permission if a person does not pass thr...

Page 15: ...e other pedestals Note The distance between the nearest two line is L 200 mm L represents the lane width 3 Slot on the installation surface and dig installation holes according to the hole position di...

Page 16: ...the low voltage cable at the entrance the two cables should be in separated conduits to avoid interference If more peripherals are required to connect you should increase the conduit diameter or bury...

Page 17: ...cable by yourself If you want to bury both of the AC power cord and the low voltage cable at the entrance the two cables should be in separated conduits to avoid interference If more peripherals are r...

Page 18: ...uld use the key to open the pedestals View the pictures below to find the lock holes Figure 3 1 Lock Holes Note Please check and avoid metal pieces dropped into the high and low voltage modules which...

Page 19: ...the installation base Steps Note The device should be installed on the concrete surface or other non flammable surfaces For opening the pedestal conveniently make sure the distance between the pedest...

Page 20: ...pedestals and the base are aligned with each other 4 Secure the pedestals with expansion bolts Note The suggested expansion bolt s size is M12 150 You can change or transform the expansion bolt accor...

Page 21: ...re 3 3 Installation Footprint 5 After installation assemble the components and screws back to the pedestal in reverse order except for protective sheets DS K3Y411X Series Flap Barrier Quick Start Guid...

Page 22: ...roy of the device 4 1 Components Introduction By default basic components of the turnstile are connected well The pedestals can communicate by wiring the interconnecting cables And the turnstile suppo...

Page 23: ...the IR boards on the left pedestal are the IR sending boards The IR boards on the right pedestal are the IR receiving boards The IR boards on the left side of the middle pedestal are the IR receiving...

Page 24: ...e Terminal N cannot be wired reversely Do not wire the input and output terminal reversely To avoid people injury and device damage when testing the ground resistance of the equipotential points shoul...

Page 25: ...one 2 core cable The picture displayed below describes the cable hole s position on the pedestals Figure 4 3 Cable Hole of Interconnecting Cable Follow the instructions below to connect the interconne...

Page 26: ...pedestal The sub lane control board will power supplied by the power adaptor For details about the wiring see the picture below Figure 4 5 Face Recognition Terminal Power Supply Wiring 4 5 Terminal De...

Page 27: ...Figure 4 6 Interface and Corresponded UART No The UART related terminals are on the access control board and BUS of the lane control board You can switch between the RS 232 and the RS 485 communicati...

Page 28: ...IP Switch No Function UART1 Note External card reader is recommended to access 485A 232A BUS of Main Lane Control Board 1 to 3 ON UART1 is RS 232A Interface 4 to 6 ON UART1 is RS 485A Interface 7 Rese...

Page 29: ...recognition terminal is recommended to access 485F 232F BUS of Sub Lane Control Board 1 to 3 ON UART3 is RS 232F Interface 4 to 6 ON UART3 is RS 485F Interface 485F 232F 7 Reserved 8 Reserved UART7 23...

Page 30: ...sub lane control board contains power input BUS interface interconnecting interface supercapacitor interface barrier position control board interface and motor drive interface The picture displayed be...

Page 31: ...ctory please connect according to actual needs Table 4 2 BUS Terminal in Main Lane Controller Terminal Name Description Lane Controller Light Board 1 Connects lane controller light board 1 Lane Contro...

Page 32: ...Reserved IR Adaptor Connects IR adaptor UART 5 Note External card reader is recommended to access Red 12 V connects 12 VDC power supply terminal Yellow 485E 232E card reader RS 485E RS 232E access ter...

Page 33: ...terminal Black GND grounding UART 6 Note External face recognition terminal is recommended to access Red 12 V connects 12 VDC power supply terminal Yellow 485F 232F card reader RS 485F RS 232F access...

Page 34: ...on Power Output 1 12 V 12 VDC Power Output G Grounding RS 485 Interface RS 485 C Connect to Card Reader RS485 RS 485 card reader ID factory DIP is 1 and 3 1 represents the passage entrance and 3 repre...

Page 35: ...exit card reader If the user has configured a guest card the exit needs to be connected to two card readers one with the DIP 4 and the other with the DIP 3 The card reader 3 and the card receiver are...

Page 36: ...ling By default there is no QR code scanner on the left pedestal of the device entrance If you need to connect an additional QR code scanner you need to connect it through the RS 232 interface here Af...

Page 37: ...ess to remaining open signals which can be linked to the host buzzer output card reader buzzer output alarm relay output door open relay output etc G Grounding C2 Event Alarm Input 2 Exit Button B2 Do...

Page 38: ...utput Relay 1 Dry Contact The alarm output supports switch output COM1 NO NC2 Alarm Output Relay 2 Dry Contact The alarm output supports switch output COM2 Loudspeaker Connect to loudspeaker Network I...

Page 39: ...IP switch of the access control board is shown in the figure below Note The diagram is for reference only Figure 4 11 DIP Switch on Access Control Board DIP A can set the device mode DIP 2 to 5 can se...

Page 40: ...ponding functions of different DIP Switch are described as follows No Device Mode UART No Function Binary Value DIP A 1 to 2 Work Mode Normal Mode Test Mode 3 Memory Mode Enable Memory Mode DS K3Y411X...

Page 41: ...Paring Mode 5 to 8 Passing Mode Controlled Bi direction Controlled Entrance and Prohibit Exit Controlled Entrance and Free Exit Free Bi direction Free Entrance and Controlled Exit Free Entrance and P...

Page 42: ...N UART 6 is RS 485F Interface 7 Reserved 8 Reserved DIP D 1 to 3 UART 1 ON UART 1 is RS 232A Interface 4 to 6 ON UART 1 is RS 485A Interface 7 Reserved 8 Reserved DIP E 1 to 3 UART 3 ON UART 3 is RS 2...

Page 43: ...erminal positions in the turnstile and their corresponded UART No are as follows Note The diagram is for reference only Figure 4 13 Interface and Corresponded UART No DS K3Y411X Series Flap Barrier Qu...

Page 44: ...Configuring Screen Parameters in User Manual of iVMS 4200 AC Client Software 4 5 8 RS 232 Wiring Note Access control board of pedestal can connect QR code scanner card recycler text screen and face r...

Page 45: ...ble the device can connect with a third party lane control board to control the third party barriers Interface D1 controls barrier opening for entrance while interface D2 controls barrier opening for...

Page 46: ...Wiring Exiting Wiring 4 5 10 Alarm Output Wiring Note For details about changing the relay output status via the jumper cap see Alarm Relay Output Mode NO NC DS K3Y411X Series Flap Barrier Quick Start...

Page 47: ...d bi direction prohibited entrance and free exit Memory Mode By default the memory mode is enabled When multiple cards are presented and authenticated it allows multiple persons passing through the la...

Page 48: ...see Manage Keyfob User of the user manual for more details The keyfob s indicator of the will flash twice if the pairing is completed 5 Set the No 4 switch to OFF and reboot the turnstile to take effe...

Page 49: ...reboot the turnstile to take effect 4 Disconnect the power and power on the device again Caution The initialization of the device will restore all the parameters to the default setting and all the de...

Page 50: ...ut Mode The jumper cap of the barrier control relay on the access control board is as below Figure 5 2 Jumper Cap Location Barrier Control Relay Output Mode The jumper cap position of barrier opening...

Page 51: ...f barrier closing NC is as below Figure 5 4 Barrier Closing NC Note The default status is NC 5 3 2 Alarm Relay Output Mode NO NC The jumper cap of the alarm relay on the access control board is as bel...

Page 52: ...Relay Output Mode The jumper cap position of alarm opening NO is as below Figure 5 6 Alarm Opening NO The jumper cap position of alarm closing NC is as below Figure 5 7 Alarm Closing NC DS K3Y411X Ser...

Page 53: ...Note The default status is NO DS K3Y411X Series Flap Barrier Quick Start Guide 41...

Page 54: ...w how to activate a device and modify its IP address For batch activation and IP addresses modification refer to User Manual of SADP for details Steps 1 Run the SADP software and search the online dev...

Page 55: ...rly Steps Note This function should be supported by the device 1 Enter the Device Management page 2 Click on the right of Device Management and select Device 3 Click Online Device to show the online d...

Page 56: ...pecially in the high security system changing the password monthly or weekly can better protect your product Proper configuration of all passwords and other security settings is the responsibility of...

Page 57: ...right side is from the low bit to the high bit When the switch is towards ON it means the switch is enabled otherwise the switch is off If you set the DIP switch like the figure displayed below its b...

Page 58: ...se Passing Visual and Audible Force Accessing None Climb over Barrier Visual and Audible Overstay Visual and Audible Passing Timeout None Intrusion Visual and Audible Free Passing Authentication Faile...

Page 59: ...t 3 Card No and fingerprint mismatch 4 Climbing over the barrier 5 Reverse passing 6 Passing timeout 7 Intrusion 8 Force accessing 9 Tailgating 10 No permissions 11 Authentication time out 12 Authenti...

Page 60: ...IR Beam Triggered 05 Lower Tenth IR Beam Triggered 22 Upper Sixth IR Beam Triggered 06 Lower Eleventh IR Beam Triggered 23 Upper Seventh IR Beam Triggered 07 Lower Twelfth IR Beam Triggered 24 Upper E...

Page 61: ...ikvision access control and video intercom devices Figure E 1 QR Code of Communication Matrix Device Command Scan the following QR code to get the device common serial port commands Note that the comm...

Page 62: ...UD23418B A...

Reviews:

Related manuals for DS-K3Y411 Series