Warning
Terminal PE should connect to a ground wire to avoid hazard when people touching the device.
Note
●
The cable bare part should be no more than 8 mm. If possible, wear an insulation cap at the end
of the bare cable. Make sure there’s no bare copper or cable after the wiring.
●
The Terminal L and the Terminal N cannot be wired reversely. Do not wire the input and output
terminal reversely.
●
To avoid people injury and device damage, when testing, the ground resistance of the
equipotential points should not be larger than 2 Ω
。
4.3 Terminal Description
4.3.1 Access Control Board Terminal and BUS Description
Access Control Board Terminal Description
You can view the access control board's terminals.
DS-K3G501SX Series Tripod Turnstile Quick Start Guide
10