Summary of Contents for DS-K2M060

Page 1: ...1 DS K2M060 Secure Door Control Unit User Manual V1 0 0 UD01462B...

Page 2: ...company website http overseas hikvision com en Please use this user manual under the guidance of professionals Trademarks Acknowledgement and other Hikvision s trademarks and logos are the properties...

Page 3: ...gy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause h...

Page 4: ...the warnings may cause serious injury or death Cautions Neglecting any of the cautions may cause injury or equipment damage Warnings All the electronic operation should be strictly compliance with th...

Page 5: ...se shall be kept from rain and moisture Exposing the equipment to direct sun light low ventilation or heat source such as heater or radiator is forbidden ignorance can cause fire danger Do not aim the...

Page 6: ...Introduction 2 1 2 Introducing the Appearance 2 1 2 1 Front View 2 1 2 2 Rear View Dial up 3 1 3 Introducing Indicators 4 Chapter 2 Installation 6 2 1 Introduction of DIP Switch 6 2 2 Wiring Cables 8...

Page 7: ...2M060 Secure Door Control Unit is the interlayer between the access control terminal and the lock including the door contact the lock the exit button the Wiegand card reader and so on It is much safer...

Page 8: ...Door Control Unit is shown as below 3 2 1 4 Figure 1 2 Rear View of Secure Door Control Unit Table 1 1 Description of Rear View No Name 1 Cable Interface of RS 485 Power LED Control etc 2 Tampering Pr...

Page 9: ...485 Communication Indicator Flicking Green The RS 485 communication is built Solid Greed The RS 485 communication is not built RELAY Indicate the lock status Green The indicator will be solid green f...

Page 10: ...on com 5 BUTTON Indicate the Exit button Green The green light is on when press the Exit button When release the button the green light will be off Notes Make sure the unit is powered on Make sure the...

Page 11: ...DIP switch module is shown below The number of DIP switch from left to right is 1 to 4 Figure 2 1 DIP Switch Module Binary Code 0000 The table shows below is the description of the DIP switch Table 2...

Page 12: ...om 7 Figure 2 2 DIP Switch Module Binary Code 0011 The DIP switch in the secure door control unit is for the RS 485 communication The code range is from 1 to 15 namely the binary code range between 00...

Page 13: ...Chapter 2 1 Introduction of DIP Switch 2 Plug the Terminal 1 to the Interface 1 as shown in Figure 2 3 and Figure 2 4 Group A Group B Group D Group E A1 A2 B1 B2 D1 D2 D3 E1 E2 E3 Power Input Sensor...

Page 14: ...rown DOOR_SENSOR Sensor Input B2 Black GND C C1 Green Black DOOR_BUTTON Door Button C2 Black GND D D1 White Purple RELAY_NC Lock Output D2 White Black RELAY_COM D3 White Red RELAY_NO E E1 Yellow RS485...

Page 15: ...he Wiegand interface F1 F2 F3 F4 F5 F6 Wiegand Brown Purple Orange Green White Black Figure 2 5 Terminals 2 The table displayed below shows the terminal 2 descriptions Table 2 3 Terminals Descriptions...

Page 16: ...Secure Door Control Unit www hikvision com 11 Interface 2 Figure 2 6 Rear View of Secure Door Control Unit...

Page 17: ...ets of the setscrews in the drilled holes 3 Plug the cables of power input lock input lock output and RS 485 as well as the Wiegand cables to the target interfaces For details please see Chapter 2 2 W...

Page 18: ...Secure Door Control Unit www hikvision com 13 The hole can be knocked down Figure 2 7 Fix on the Wall...

Page 19: ...Secure Door Control Unit www hikvision com 14 Chapter 3 Wiring External Device The figure displayed below is the wiring introduction of external device Figure 3 1 External Device Wiring 0100001060602...

Page 20: ...Secure Door Control Unit www hikvision com...