English
16
TROUBLESHOOTING
Use the inspections in the table below if the tool does not operate normally. If this does not
remedy the problem, consult your dealer or the HiKOKI Authorized Service Center.
Symptom
Possible cause
Remedy
Tool doesn’t run
No remaining battery power
Charge the battery.
Tool suddenly stopped Tool was overburdened
Get rid of the problem causing the
overburden.
The battery is overheated.
Let the battery cool down.
Poor suction
Dust case is full.
Dispose the dust.
Nozzle is plugged.
Remove the obstruction.
Nozzle or extension pipe is loose. Firmly tighten the unit.
Nozzle or extension pipe is
cracked or damaged.
Exchange the unit with a new one.
Filter or pre
fi
lter is clogged.
Turn the dust case and scrape
o
ff
dust with dust removal blade,
or remove the
fi
lter/pre
fi
lter and
lightly strike it or wash with water.
Exhaust or the main
unit is hot
The motor is overheating because
the dust case is full, or the
fi
lter/
pre
fi
lter is clogged.
Dispose the dust. Or else, clean
the
fi
lter/pre
fi
lter.
Abnormal noise/foul
odor
Filter or pre
fi
lter in not properly
installed, resulting in foreign
matter getting into the motor.
Remove the dust case, point the
intake port downward and gently
shake to remove foreign matter
and dust.
Should abnormal noise/foul
odor persist, the motor may
be damaged. Immediately
discontinue use and arrange for
repairs.
000Book̲R10DAL̲ChS.indb 16
000Book̲R10DAL̲ChS.indb 16
2017/12/07 17:19:59
2017/12/07 17:19:59