50
Enforcer V10 Programming Guide
TIMER
FUNCTION
RANGE
Wireless Supervision Time
This option is only applicable if wireless devices are installed. It
is the time window before a wireless supervision fault will be
signalled. For example: if the time is set for 2 hours, then any
device that doesn’t communicate with the wireless expander
within that period will cause a supervision fault. This must be
programmed to 2 hours or less for compliance to EN50131.
0-99 hours
Wireless Jamming Time
This option is only applicable if wireless devices are installed.
It is the time window that if a wireless device had its signal
‘blocked’ a fault would display. For example, if the time is set to
30 seconds, then if a wireless device is ‘jammed’ longer than 30
seconds a fault will be displayed. This must be programmed to
30 seconds or less (but not zero) for compliance to EN50131.
0-100 seconds
Service Time
This is a timer that can be set in days, and will display a message
to the user warning that a service is due. An engineer code will
clear the message.
367 days
APPENDIX D. OUTPUT TYPES
NO.
TYPE
ACTIVE
RESTORE
0000
Not Used
(Permanently off )
0001
Fire
At alarm
When a valid code is entered
0002
Hold Up Any
"At a HU or Duress alarm
(This includes keypad HU)"
When a valid code is entered
0003
Intruder Any
At alarm, while system is
disarmed
At first valid code entry and at
end of confirm time.
0005
Misoperation Any
(Abort)
When system is silenced after any
‘intruder’ output is triggered
After 2 minutes
0006
Confirmed Any
After two ‘intruder’ alarm
activations
At next code entry
0007
Tamper Any
Any tamper alarm
At code entry to silence And at
end of confirm time.
0008
Duress
At a Duress alarm (i.e. from a
keypad)
When a valid code is entered
0009
HU Device Any
At alarm on a HU input only
When a valid code is entered
0010
Gas
At alarm
When a valid code is entered
0011
Set Fail
Pre-set time after start of exit
time, if exit procedure is not
complete
At code entry to rearm
0012
Entry Deviation
When deviation from entry route
occurs, during entry time
At code entry to unset
0013
Secure Intruder Any
At alarm, after exit time started,
until unset
At first valid code entry and at
end of confirm time.