SolaFrame Theatre v1.2.5
48
User Manual
Gobo Wheel 1 Er
(Gobo Wheel 1- error) This message will appear after the reset of the fixture if the magnetic-indexing
circuit malfunction (sensor failed or magnet missing) or the stepping-motor is defective (or
it’s driving
IC on the main PCB). The Gobo Wheel 1 is not located in the default position after the reset.
Gobo Rot. 1 Er
(Gobo Rot. 1- error) This message will appear after the reset of the fixture if the magnetic-indexing
circuit malfunction (sensor failed or magnet missing) or the stepping-motor is defective (or
it’s driving
IC on the main PCB). The Gobo Rot. 1 is not located in the default position after the reset.
Gobo Wheel 2 Er
(Gobo Wheel 2- error) This message will appear after the reset of the fixture if the magnetic-indexing
circuit malfunction (sensor failed or magnet missing) or the stepping-motor is defective (or
it’s driving
IC on the main PCB). The Gobo Wheel 2 is not located in the default position after the reset.
Focus Er
(Focus - error) This message will appear after the reset of the fixture if the magnetic-indexing circuit
malfunction (sensor failed or magnet missing) or the stepping-motor is defective (or
it’s driving IC on
the main PCB). The Focus is not located in the default position after the reset.
Zoom Er
(Zoom - error) This message will appear after the reset of the fixture if the magnetic-indexing circuit
malfunction (sensor failed or magnet missing) or the stepping-motor is defective (or
it’s driving IC on
the main PCB). The Zoom is not located in the default position after the reset.
Animation Er
(Animation - error) This message will appear after the reset of the fixture if the magnetic-indexing
circuit malfunction (sensor failed or magnet missing) or the stepping-motor is defective (or
it’s driving
IC on the main PCB). The Animation is not located in the default position after the reset.
Blade Rot Er
(Blade Rot - error) This message will appear after the reset of the fixture if the magnetic-indexing
circuit malfunction (sensor failed or magnet missing) or the stepping-motor is defective (or
it’s driving
IC on the main PCB). The Blade Rot is not located in the default position after the reset.
Summary of Contents for SolaFrame Theatre
Page 1: ...Professional Moving Head User Manual Version 1 2 5 Revision A ...
Page 7: ...SolaFrame Theatre v1 2 5 7 User Manual Declaration of Conformity ...
Page 8: ...SolaFrame Theatre v1 2 5 8 User Manual ...
Page 16: ...SolaFrame Theatre v1 2 5 16 User Manual Photometric data image ...
Page 19: ...SolaFrame Theatre v1 2 5 19 User Manual ...