Hides BR-101E Quick Installation Manual Download Page 19

    Easy HD Expressway! 

BR-101E QIG 

 

WWW.HIDES.COM.TW

  

18 

 

 

8.

 

Tool Usage- Initialize EEPROM 

Set DTV bridge board in configuration mode by removing Jumper J1. 

 

Connect USB port to your PC. 

In the start menu, launch “DTV Bridge Controller”. 

 

If device is not found,   

 

Please check, 

a. if USB cable is connected well 

b. Jumper J1 is removed properly. 

c. IT9517 Driver is installed well in Device Manager. 

 

If device is found, 

 

Summary of Contents for BR-101E

Page 1: ...Repeater Gap Filler Quick Installation Guide Revision Log Revision Date Author Remarks 0 1 2013 11 21 First draft 0 2 2013 12 04 Call sign configuration 0 3 2013 12 18 EEPROM Re init 0 4 2014 01 23 UV...

Page 2: ...eck LED State 4 4 Setup PC NB environment for configuration 6 4 1 Run Setup exe to install configuration software on your PC NB 6 4 2 Remove Jumper J1 for USB configuration mode 6 4 3 Connect USB port...

Page 3: ...The flexibility makes BR 101E a handy converter for frequency bandwidth and modulation conversions between the received and transmitted channels Basically BR 101E receives a DVB T channel demodulates...

Page 4: ...ation mode 2 USB Provide system power 5V DC 400mA required at full operation Connect to PC NB for configuration 3 MCX type connector DVB T Tx RF output 4 MCX type connector DVB T Rx RF input 5 Jumper...

Page 5: ...WW HIDES COM TW 4 3 Easy Repeater Setup 3 1 Short Jumper J1 3 2 Connect RF in out cable The RF in connector is IEC type and the RF out is F type 3 3 Apply 5V DC Power to the USB connector 3 4 Check LE...

Page 6: ...HIDES COM TW 5 If the RF in is present and tuned well the Lock LED will be on The factory default settings for RF in is 474MHz 8MHz BW and the RF output is 666MHz 8MHz BW To customize the settings ple...

Page 7: ...oftware on your PC NB In the start menu a new submenu DTV Bridge Controller will be created 4 2 Remove Jumper J1 for USB configuration mode 4 3 Connect USB port to your PC NB 4 4 Driver install In the...

Page 8: ...Easy HD Expressway BR 101E QIG WWW HIDES COM TW 7...

Page 9: ...d in configuration mode by removing Jumper J1 Connect USB port to your PC In the start menu launch DTV Bridge Controller If device is not found Please check a if USB cable is connected well b Jumper J...

Page 10: ...HIDES COM TW 9 Click on Connect to continue Click on Configure to continue Note If there is any error message as shown below Please click on Init EEPROM to initialize EEPROM properly Refer to the cha...

Page 11: ...ngs Specify the channel frequency and bandwidth for receiver The bandwidth supported depends on the jumper J2 of the receiver module The I2C address should be 0x3A for BR 101 and 0x38 for BR 100 Jumpe...

Page 12: ...mance but it s optional and can be ignored 6 PCR restamp and cell ID DTV Bridge board supports PCR restamp feature to fix PCR jitter while modulation It s optional to enable it and three restamp mecha...

Page 13: ...oard in configuration mode by removing Jumper J1 Connect USB port to your PC In the start menu launch DTV Bridge Controller If device is not found Please check a if USB cable is connected well b Jumpe...

Page 14: ...1E QIG WWW HIDES COM TW 13 Click on Connect to continue Click on Update FW to continue Click on buttons to browse and specify the firmware files then click on Update button to start flashing new firmw...

Page 15: ...Easy HD Expressway BR 101E QIG WWW HIDES COM TW 14 When firmware update is done set DTV bridge board in normal operation mode by short Jumper J1 Then power off and power on to reset...

Page 16: ...ard in configuration mode by removing Jumper J1 Connect USB port to your PC In the start menu launch DTV Bridge Controller If device is not found Please check a if USB cable is connected well b Jumper...

Page 17: ...Easy HD Expressway BR 101E QIG WWW HIDES COM TW 16 Click on Connect to continue Click on Set Call Sign to continue...

Page 18: ...the new PID number New PID which should be the same as the video PID of the missed RF input Period sec specify how long call sign should be sent When the period expires Tx RF out will be shutdown When...

Page 19: ...board in configuration mode by removing Jumper J1 Connect USB port to your PC In the start menu launch DTV Bridge Controller If device is not found Please check a if USB cable is connected well b Jump...

Page 20: ...EEPROM to continue Click on Update FW to continue Click on buttons to browse and specify the template firmware Image file then click on Init button to start initializing the board EEPROM Note in the...

Page 21: ...Easy HD Expressway BR 101E QIG WWW HIDES COM TW 20 image file When initialization is done set DTV bridge board in normal operation mode by short Jumper J1 Then power off and power on to reset...

Page 22: ...Easy HD Expressway BR 101E QIG WWW HIDES COM TW 21 9 Filter Specifications 9 1 BR 101E DTV Bridge Board U V Filter Design Default BR 101E UHF LPF 950MHz Recommended 1350MHz LPF...