background image

 

 

FlexSmart™ 607X Series Installation Guide – 6075-900, B.2

 

Notes: 

 

Keypad outputs only available 

 

The system must have a single earth ground point.

 

 As 

shown, 

do not connect shield (screen) wire at reader cable splice. 

 

For open collector 

(non-terminated output), 

consult your system manufacturer for correct cable length 

and type.

 

Regulatory 

FCC 

This device complies with part 15 of the FCC rules.  Operation is subject to the following two conditions: 
(1) this device may not cause harmful interference, and (2) this device must accept any interference 
received, including interference that may cause undesired operation.  

Changes or modifications not expressly approved by the party responsible for compliance could void the 
user’s authority to operate the equipment. 

UL 

This reader is intended to be used with UL294 Listed Control Equipment. 

CE 

Hereby, HID declares that this proximity reader is in compliance with the essential requirements and other 
relevant provisions of Directive 1999/5/EC. 

Models 

Readers 

6075

 

HID Format MIFARE Reader 

6076

 

Custom MIFARE Reader 

6077

 

Custom DESFire Reader 

Keypad Readers 

6071

 

HID Format MIFARE Reader 

6072

 

Custom MIFARE Reader 

6073

 

Custom DESFire Reader 

February 5, 2007 

 

Page 7 of 8 

© 2007 HID Global Corporation.  All rights reserved. 

 

Summary of Contents for FlexSmart 607 Series

Page 1: ...292 Jeronimo Road Irvine CA 92618 1905 HID FlexSmart 607X Series Readers INSTALLATION GUIDE 2007 HID Global Corporation All rights reserved February 5 2006 Document Number 6075 900 Document Version B...

Page 2: ...tents 1 Overview 3 2 Mounting 4 3 Wiring 5 Regulatory 7 Models 7 Contact 8 List of Figures Figure 1 Reader Dimensions and Mounting 4 Figure 2 Keypad Reader Dimensions and Mounting 5 Page 2 of 8 Februa...

Page 3: ...with FlexSmart readers 1 Installation Guide 2 MIFARE reader module for Slim or Wall switch 3 Cover Bezel reader only 1 3 Specifications Supply Voltage 9VDC to 16VDC Supply Current 15 75mA Keypad 25 1...

Page 4: ...ing the Reader Format The reader format is found on the ID label see below which is located on the reader electronics module Reader Format 2 Mounting Figure 1 Reader Dimensions and Mounting Page 4 of...

Page 5: ...le to the controller 4 Using the two 6 32 or M 3 screws attach the reader to the first two mounting holes 5 Once the reader module is screwed in place snap on the bezel 3 Wiring 3 1 Cable Types and Ma...

Page 6: ...ke certain the DC resistance between your established earth ground and the system ground is 50 Ohms or less If a direct connection to a ground rod is not possible connect the reader to an earth ground...

Page 7: ...rference received including interference that may cause undesired operation Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to o...

Page 8: ...90 Europe Middle East and Africa HID Corporation Ltd Haverhill UK email eusupport hidcorp com main 44 0 1440 714 850 support 44 0 1440 711 822 fax number 44 0 1440 714 840 Asia Pacific HID Asia Pacifi...