HID EdgePlus Quick Installation Manual Download Page 10

EdgeReader and EdgePlus Installation 

 

Part No. 82000-901 

 

Update System 

Update System allows the user to update the firmware on the Edge device.  During a download the 
Edge device image flashes between grey and yellow.  When a download completes the image color 
changes to green for success or red for failure.  If the download fails, a tool tip with the error status code 
may be viewed by hovering the mouse over the image.   

Note

: Depending on the system, it may take several minutes to completely download. 

Network Defaults Jumper 

The 

Network Defaults Jumper

 requires that someone with physical access to the Edge device place 

a jumper over the P65 header prior to the rebooting the device. The Edge device reconfigures its 
network settings to the factory defaults when the jumper is on the header. From this point, 
configuration (or re-configuration) will proceed normally. 

Use the 

Network Defaults Jumper

 to correct potential errors in an Edge device network configuration. 

CAUTION: Upon rebooting the Edge device (with a jumper in place,) all network configuration 
information will be overwritten.

 

 

Figure 1 Network Defaults Jumper 

1.  Remove the jumper from Tamper header  

2.  Place the same jumper over the left two pins of the P65 header (as shown in Figure 1 Network 

Defaults Jumper). 

3.  Reboot the Edge device to change all of the configuration settings back to the factory defaults. 

4.  After the LED turns amber, remove the jumper from the P65 header, returning it to the tamper 

header. Upon removing the jumper it takes approximately 60 seconds for the Edge device to 
reset. Once the reset is complete, the LED will return to green. 

5.  Configure the Edge device for your installation parameters. 

April 2007 

 

Page 10 of 14 

© 2007 HID Global Corporation. All rights reserved. 

Summary of Contents for EdgePlus

Page 1: ...9292 Jeronimo Road Irvine CA 92618 1905 EdgeReader EdgePlus Quick Installation Guide 2006 HID Global Corporation All rights reserved Document Version 1 4 April 27 2007 Document Number 82000 901A 2...

Page 2: ...p 1 Connect 5 1 1 Wiring the Edge Device 5 Step 2 Contact 5 2 1 Discovery Client 6 2 2 Virtual Port 6 Step 3 Configure 6 3 1 Edge Device Communications 8 Step 4 Communicate 9 Appendices 9 Troubleshoot...

Page 3: ...ct Specifications Description Specification Power Supply 12 16VDC or Power over Ethernet PoE Maximum current at 12VDC per EdgeReader 1 Amp Average operating current at 12VDC 300 mA ERW400 EdgeReader a...

Page 4: ...dgeReader and EdgePlus Installation Part No 82000 901 Overview The following outlines what is required to install the Edge device April 2007 Page 4 of 14 2007 HID Global Corporation All rights reserve...

Page 5: ...nal but before the Edge device s has been configured At this point all of the Edge devices on a network will have the same host name and unknown IP addresses assuming a DHCP environment In this scenar...

Page 6: ...121 1 Ensure you are running a Windows 2000 or XP computer 2 Disconnect your Windows computer from its hub or network 3 Connect the Windows computer to the Edge device with an Ethernet cable Start bu...

Page 7: ...3 1 2 2 DHCP Network If using a DHCP TCP IP network this information is configured automatically 3 1 2 3 Modem Configuration Checklist If using a Modem proceed with changes using the information coll...

Page 8: ...he settings appropriately Step 4 Communicate Now the Edge device is connected contacted and configured 1 Reboot the Edge device by removing and reconnecting the power supply The Edge device should be...

Page 9: ...g functionality Configure configure inputs outputs and door characteristics System Time update System Time Update System updates the firmware Configure Configure provides the ability to view and modif...

Page 10: ...is on the header From this point configuration or re configuration will proceed normally Use the Network Defaults Jumper to correct potential errors in an Edge device network configuration CAUTION Upo...

Page 11: ...ewall for the network contact the Network IT administrator or manager CAUTION If the firewall is not configured properly the Edge device cannot communicate with the host Contact Information Americas H...

Page 12: ...pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment...

Page 13: ...EdgeReader and EdgePlus Installation Part No 82000 901 Intentional Blank April 2007 Page 13 of 14 2007 HID Global Corporation All rights reserved...

Page 14: ...tional AC Electrical Outlet or Surge Protector Optional Configuration Data Connection Type DHCP DHCP data required in gray Static Edge Device IP Address Subnet Mask Default Gateway Primary DNS Server...

Reviews: