INSTALLATION GUIDE
An ASSA ABLOY Group brand
EDGE EVO
82000-921, Rev. D.3
Page 5
2
Mounting
3
Wiring
Hi-O Group Select Jumper
Short = Group 1, Open = Group 2
Outside Door
Inside Door
( )
1
P2
12
1
P1
4
CAN V+
GND
CAN_H
CAN_L
RDR PWR
GND
Data0 / Data
Data1 / CLK
*
GRN LED
RED LED
Hold
*
Beep
GRP SEL
+
-
10
P3
14
P1
1
+
-
Hi-O Group Select Jumper
Short = Group 1, Open = Group 2
Outside Door
Inside Door
( )
+
-
*
NC
NO
COM
NC
NO
COM
Relay Jumpers
6
P1
0
1
AUX
+DC
AUX
GND
+
-
Reader
Door Strike
AU
X
AC FAIL
INPUT SENSE
REX
Door Mon
* = Built-In Module Internal Optical Tamper Disable
BATT FAIL
INPUT SENSE
Note:
Connect the Door Monitor to avoid a Force Door Alarm.
P9 P5 P8 P6 P4 P7
Ethernet / PoE
Auto-Detected
Activity LED
Link LED
Hi-O CANbus
Reader Tamper -
CAP
Restore Network
Defaults Jumper
CAUTION: Some magnetic locks exhibit both high inrush current when activated and a high
instantaneous break voltage when de-energized due to magnetic field collapse. It is recommended
you use of a snubber circuit across the controlling relay terminals to protect the controlling relay
contacts. Go to
www.hidglobal.com
> Support and search for "Edge Solution 891" to access
How do I
wire a High In-Rush Current locking device to VertX/EDGE EVO
. Not evaluated by UL.
Optional
Supervised Inputs
1-6K
N/O
1-6K
N/C
1-6K
1-6K
N/O
Legend
CAN_H
= Hi-O CANbus High
CAN_L
= Hi-O CANbus Low
GND
= Ground
CAN V+
= Hi-O CANbus Positive
Supply
ATTENTION
Observe precautions for handling
ELECTROSTATIC SENSITIVE DEVICES
Junction box not included.