SERVICE 10
AQUATECH OPERATIONS, SERVICE AND PARTS MANUAL
A Product of Hi-Vac Corporation
SERVICE
X-VAC STANDARD UNIT LUBRICATION POINTS INTERVALS
LUBRICATION CHART
Revised3/1/2019
ITEM
CAPACITY
OIL RECOMMENDATION
AMBIENT TEMP.
INTERVAL
Aquatech Water Pump Gear Reduction Boxes **
2.5 Quarts
SAE 90 EP
SAE 60 EP
Winter
SAE 90 EP
Summer
Cummins A1700 37hp
5 Quarts
Cummins A2300 50hp
7.5 Quarts
Cummins B3.3 65hp & 85hp
8 qts. (9 w/turbo)
Cummins B3.9 116hp & 125hp
?
Cummins B5.9 160hp
?
ISO VG100 EP3 Non-Corrosive
Below 32°F (0°C)
ISO VG220 EP5 Non-Corrosive
Above 32°F (0°C)
General PN3 Regulating Valve
15.2 Ounces
General PN4 Regulating Valve
8.5 Ounces
General HF Series Water Pumps - Crankcase
2.13 Quarts
General MH Series Water Pumps - Crankcase
14.8 Quarts
General MK Series Water Pumps - Crankcase
14.25 Quarts
General MWR Series Water Pumps - Crankcase
9.5 Qaurts
General KL Series Water Pumps - Crankcase
3.75 Quarts
General MS Series Water Pumps - Crankcase
10.57 Quarts
General MS Series Water Pumps - Packings
1 squirt each zerk A111370 (3oz. tube) Grease
A111372 (12oz. tube)
All
500 hrs
or 12 mo. ¤
General EZ Series Water Pumps – Crankcase
14 oz.
ISO VG100 (SAE30 ND)
Giant Water Pumps – GP & LP Series
see manual
80W90
Giant Water Pumps – P200, P300 & P400 series
see manual
20W50 Synthetic (Giant p/n 01153)
Hibon Blower model SIAV840 (vertical gears)
.52 Gal. Drive End
.45 Gal. Non D. E.
Hibon Blower model SIAV8702 (vertical gears)
.79 Gal. Drive End
.59 Gal. Non D. E.
Hibon Blower model TS56MV18
.5 Gal. Drive End
1.11 Gal. Gear End
Hibon Blower models VTB810H & VTB820H (vert.)
1.23 pt. ea. end
Hi-Vac Bag Shaker Motor Gear Reducer
8 oz.
Mobil SHC-634 (ISO 460 PAG)
-10°F to 120°F
Top Off
Hydraulic System (for all product lines)
see manual
AW46 (Formerly AW68 *)
All
MD Pneumatic Blower **
see manual
ISO VG220 EP5
Myers C Series Pumps **
2 Quarts
SAE 30 Gear Oil
All
300 hrs
Myers D Series Pumps **
see manual
Mobilgear 630 (ISO VG220 EP5)
All
300 hrs
OMSI Direct/Mechanical Driven Units
see manual
SAE 80W90 (Moderate Duty Cycle)
SAE 75W90 GL-5EP (Heavy/Severe)
All
1000 hrs
OMSI PC4-3000 PowerClutch™ Driven Units
8 Quarts
Mobil Delvac No.1
All
500 hrs
Robuschi Blower **
see manual
ISO VG220 EP5
Roots 624 Blower (vertical gears)
32 oz. Drive End
64 oz. Gear End
Roots 624 Blower (horizontal gears)
64 oz. Drive End
96 oz. Gear End
Roots 824 Blower (vertical gears)
8 oz. Drive End
2 pt. Gear End
Sutorbilt Blower
see manual
ISO VG220 EP5
0°C to 90°C
Uraca KD716GS Water Pump
see manual
SAE 75W90 GL5 Synthetic
Uraca P3-45 Water Pump
see manual
ISO VG220 EP5 or SAE 85W90
Uraca MSSV Safety & Unloading Valve
.5 L
ISO VG46
Uraca MSUV Safety & Unloading Valve
.51 L
ISO VG5
Above 80°C use Full
Synthetic
12 Mo.
(VG) Viscosity Grade: a commercial rating of industrial lubricants. The grade numbers are approximately equal to the kinematic viscosity of the
lubricant in centistokes. A table is provided showing the range of viscosities acceptable for each grade under the current standard of the
International Organization for Standardization (ISO).
500 hrs
or 6 mo. ¤
1000 hrs
or 12 mo. ¤
500 hrs
or 12 mo. ¤
Below 0°F (-18°C)
0° to 32°F (-18° to 0°C)
32° to 90°F (0° to 32°C)
Above 90°F (32°C)
500 hrs
Mobil SHC-630 (ISO VG220 Synthetic)
Aquatech "Fab" Water Pump model 012 **
no record
1000 hrs
2 Gallons
Gaso 3364 Series Water Pumps **
2000 hrs
or 6 mo. ¤
ISO VG46
All
ISO VG220 R&O
ISO 100 (AGMA 3EP)………………..
ISO 150 (AGMA 4EP)………………..
ISO 220 (AGMA 5EP)………………..
ISO 320 (AGMA 6EP)………………..
Winter & Summer
* Was changed in 2009 to accommodate the use of the Pall filters. ** Used pre Hi-Vac
¤ Whichever occurs first
Below 20°F
-25°F to 20°F
Above -10°F
SAE 5W-30 - API Spec CH4 & up…...
SAE 10W30 - API Spec CH4 & up…..
SAE 15W40 - API Spec CH4 & up…..
12 mo.
32° to 113°F
All
Keep Full
Note: synthetic has been recommended since 2005