background image

1

1

CONTENTS

FEATURES ……………………………

CONTENTS ……………………………

01

SAFETY INFORMATION  …………… 02 
PARTS NAME …………………………

04

- Front / Rear …………………………… 04

WATER FILTRATION PROCESS   ……

04

- Brenna (HTW-07-B-C)  ………………

05
05

INSTALLATION   ………………………

05

     
HOW TO USE …………………………

06

- To Drink Room Water  ……………… 06
- To Perform the Continuous Extraction    06

 

FILTER REPLACEMENT  …………… 07
-  Filter Replacement Cycle …………… 07
-  Filter Replacement Method ………… 07

SPECIFICATION ..................…………

09

 

 

2

SAFETY INFORMATION

 Danger: If not observed, serious injury or even death may occur as a result.

Do not use a damaged power plug or a loose electric outlet. (Brenna only)
 Electric shock or fire may occur as a result. 
Do not pull the power cord or touch the power plug with a wet hand. (Brenna only)
Electric shock or fire may occur as a result.
Do not forcefully bend the power cord or put it under a heavy object to prevent it from being 
damaged or deformed. (Brenna only)
Otherwise electric shock or fire may occur as a result.
If the power cord is wet, unplug the unit and let it completely dry before subsequent use.
Otherwise, electric shock or fire may occur as a result.
Unplug the product before repair, inspection, or parts replacement. (Brenna only)
Otherwise, electric shock may occur as a result.
Do not plug into an outlet that is being used by several other appliances. Use an electrical outlet 
dedicated. (Brenna only)
Otherwise, fire may occur as a result.
When you don’t use for a long time, close the main water supply valve and unplug. (Brenna only)
Otherwise, electric shock or fire may occur as a result.
Do not attempt to repair the power cord.
Do not connect and pull out the power plug repeatedly. (Brenna only)
Otherwise, electric shock or fire may occur as a result.
Remove any dust or water off in the pin and contacts of the power plug. (Brenna only)
An electric shock or fire may occur as a result.
In the case the power cord is damaged, do not replace the cord yourself. Call Hi-Tech Service 
Center to have it replaced. (Brenna only)
Otherwise, electric shock or fire may occur as a result.
Do not install near a heating device.
Otherwise, fire may occur as a result.
When the water is coming inside of the product or there is a puddle on the product, call Service 
Center after closing the supplying valve and unplugging. (Brenna only)
Otherwise, electric shock may occur as a result.
Do not put the candle, a light for cigarette on the products.
Otherwise, fire may occur as a result.
If our product produces a strange noise or odd smell, immediately unplug from the electrical outlet 
and call our Service Center. (Brenna only)
Otherwise, electric shock may occur as a result.
Do not place any containers with water, medicine, food, small metallic objects, or any flammable 
material on the top of the product.
In the case foreign material gets inside the product, electric shock, fire, product damage may 
occur as a result.
Clean after unplugging, and don’t clean by spraying the water directly or don’t wipe the product 
using the benzene and thinner.
Otherwise, electric shock or fire may occur as a result.
Do not move the product by pulling the power cord. (Brenna only)
Otherwise, electric shock or fire may occur as a result.

OUR NETWORK ……………………… 10

 

Summary of Contents for BRENNA HTW-07-B-C

Page 1: ...1 261 3056779 3053079 Fax 91 261 2234907 HO Off BARDOLI Tel 91 2622 222755 224726 Fax 91 2622 227315 Branches AHMEDABAD ANAND BARODA BHARUCH 91 99740 15852 DHULE 91 2562 272544 KAMREJ 91 99740 15846 MUMBAI 91 22 28756109 NADIAD 91 99740 15854 NANDURBAR 91 2564 229087 NASHIK 91 253 2597249 NAVSARI 91 99740 15853 PETLAD 91 99740 15855 UMRETH 91 99740 15856 VALSAD 91 98980 47609 VAPI 91 99740 15857 9...

Page 2: ... a result Do not attempt to repair the power cord Do not connect and pull out the power plug repeatedly Brenna only Otherwise electric shock or fire may occur as a result Remove any dust or water off in the pin and contacts of the power plug Brenna only An electric shock or fire may occur as a result In the case the power cord is damaged do not replace the cord yourself Call Hi Tech Service Center...

Page 3: ... the saved water completely and emptying the newly purified water once again The saved water can be polluted Do not use the purified water for changing the water in the fish ball aquarium Do not turn by gripping the purified water extraction faucet or do not lift the product using the faucet Otherwise leakage or product damage may occur as a result 4 Front Rear 1 Sliding lever 2 Extraction faucet ...

Page 4: ... USE Shall install the adaptor with connector on the cold water pipe Flush water through each filter at least 5 minutes before Connection 1 Step 2 Neo sense filter Step 3 Membrane filter RO daily life water Step 4 Post carbon block filter particles or dust and to improve taste of water Step 5 Ceramic filter This ceramic filter has the function to control microorganism propagation in water This Neo...

Page 5: ...nse filter 6 months Membrane filter RO 24 months Post Carbon bloc filter 18 months Ceramic filter 12 months Filter name Usable Period Neo sense filter 6 months Post Carbon bloc filter 18 months Membrane filter UF 12 months Ceramic filter 12 months 1 5 2 3 4 8 3 Separate the fitting connected to the filter to replace and then replace the filter Separate the fitting using an appropriate tool 4 After...

Page 6: ...to change for the purpose of improving the performance of the product 9 10 SPECIFICATION OUR NETWORK HEAD OFFICE MKTG OFFICE BRANCHES DEALERS MFG UNIT AHMEDABAD RAJKOT VADODARA NASHIK MUMBAI INDORE JAIPUR UDAIPUR KOTA DELHI JODHPUR CHITTOR BHILWARA SIKAR JALORE HYDERABAD SURAT DHULE BHARUCH ANAND JUNAGADH HIMMAT NAGAR BARDOLI JALGAON NANDURBAR AKOLA BANGALORE CHENNAI KOLCUTTA PARWANOO BILASPUR TRI...

Reviews: