58
Mode: used to select the working mode of the distance
measuring device.
Use keys ▲▼ to move the indicator „>‟ to the wanted opt.
Press „ENT‟ to save setting. When selecting Rept (repeated),
move indicator „>‟ to it and use keys
◀▶
to choose the times for
repeated measurement. The number of times can be between 3
and 9.
On the Second Page:
Offset: Enter off-center (eccentric) measurement
See reference in8.Offset
Stake: Stake out distances:
The key „Mode‟ under this page is to switch the typed in
distance between HD, VD and SD. The initial mode of typed in
distance is HD. When finishing entering, press soft key „Enter‟
Stake-out by distance
HD:
B.S
Clear
Mode