Installation BN48-IP66
22
Release 01 11/2019
EMC and immunity
EMC interference
emission
Radiated emission
FCC 47 CFR Part 15
Class A
EN 55032
Class A
Conducted emission
FCC 47 CFR Part 15
Class A
EN 55032
Class A
EMC interference
immunity
Electrostatic discharge
EN 61000-4-2
IEEE C37.90.3
Contact discharge
± 6 kV
EN 61000-4-2
IEEE C37.90.3
Air discharge
± 8 kV
Electromagnetic field
EN 61000-4-3
80 MHz ... 6000 MHz
10 V/m
Fast transients (burst)
EN 61000-4-4
Power
± 2 kV
EN 61000-4-4
Signal
± 1 kV
Voltage surges - AC
supply connection
EN 61000-4-5
line/earth
± 2 kV
EN 61000-4-5
line/line
± 1 kV
Voltage surges - data line
EN 61000-4-5
line/earth
± 1 kV
Conducted disturbances
EN 61000-4-6
150 kHz ... 80 MHz
10 V
Network range
10/100/1000 Mbit/s twisted pair
port
Length of a twisted pair segment
max. 109 yards (100 m) (for Cat5e cable)