User Manual
第
13
页 共
30
HLK-B35
Query
instruction
at+uart=?
at+uart=?
115200,8,n,1
Note: Query the serial port baud rate, data bit,
validation, stop bit
3.1.6.
Query MAC address:at+Get_MAC
Type
Grammar
Return and description
Query
instruction
at+Get_MAC=?
at+Get_MAC=?
40:d6:3c:15:5f:e8
Note: Reply to the mac address of the module
3.1.7.
Rest:at+default
Type
Grammar
Return and description
Set
instruction
at+default=1
at+default=1
OK
Note
:
module reset
3.1.8.
Save the set parameters:at+net_commit
Type
Grammar
Return and description
Set
instruction
at+net_commit=1
at+net_commit=1
Ok
Note
:
Submit the setting parameters successfully
3.1.9.
Module restart or enter transparent transmission mode:at+reconn
Type
Grammar
Return and description
Set
instruction
at+reconn=1
at+reconn=1
Ok
Note: when the instruction is executed before
at+net_commit=1
Instruction, the module will restart
When the at+net_commit=1 instruction has not
been executed before executing this instruction,
The module will enter the transparent
transmission mode