![Heylo BT 500 S User Manual Download Page 19](http://html.mh-extra.com/html/heylo/bt-500-s/bt-500-s_user-manual_2128337019.webp)
19
EN
Connection of the drain hose
At the connection of the tank, a ¾ in. drain hose can be connected which automatically drains water
from the tank through a gradient.
Display E
„REMOTE“ control)
The display E lights up red when an external hygrostat is plugged into the socket 2.
When the hygrostat triggers the dryer, the display is not lit. When the drying stage is reached and the
drier is switched off, the display E will light up again.
Display C (Display)
Display C will display the version number of the electronics software (such as 0100, for example) for
about 4 seconds when connected to power (connecting the plug). For more displays, please refer to
chapter (7) (trouble shooting).
Display D (RUN) (display is active when unit is operating only).
If the display is off, the unit is in break mode (air humidity set has been reached, for example). If the
display is flashing, the unit is in the defrosting phase or compressor delay after having been switched
on (takes up to 210 s.).
Display E (FULL)
Display E lights up red when the condensate tank is full.
Display F (REMOTE)
When the “REMOTE” function (control of the unit by external hygrostat) has been activated, the
“REMOTE“ display will be lit.
Using an external hygrostat:
Function “REMOTE” (remote control element): An external hygrostat can be connected to the unit. For
use, the hygrostat has to be plugged into socket (1).
Connection socket
for external hygrostat
Hygrostat article No.: 1110552
ATTENTION:
Check whether the operational noise from the blower and compressor is correct before
leaving the unit unattended.