Configuration and Operation
LD8 Operations Manual
AB- V-MA-00635_RevA6
21
4.5 Ethernet Configuration
Network connectivity to the LD8 is essential f or configuration and implementing changes. The f ollowing sub-
sections detail how to check and change the present IP address settings.
4.5.1 IP Configuration via WebUI
IP addresses can be checked and configured by navigating to
Settings > Networking
. Within the
Ethernet
Window, the
DHCP
setting can be toggled to
Off
or
On
. Toggling DHCP to Off will allow for Static IP address
details to be input. Note the Wi-Fi related features are unavailable at present.
NOTE
If no connectivity via Ethernet is available, commands can also be sent through the Serial
COM ports.
4.5.2 Checking IP and Subnet Status via Terminal
To check the current IP settings of the LD8 enter the command below:
LOG IPSTATUSA ONCE
IP and subnet settings will be returned, proceeded by
ETHA
, within quotation marks as highlighted below:
IPSTATUSA,WCOM1_30,0,65.0,FINESTEERING,2043,203989.000,02008020,7fe2,14970;2,
ETHA,"192.168.1.123","255.255.255.0","192.168.1.1",WIFI,"192.168.19.1, "255.255.
255.0","",1,"0.0.0.0"*d9d1437c