Configuration and Operation
LD8 Operations Manual
AB- V-MA-00635_RevA6
13
4 Configuration and Operation
There are two ways in which the LD8 can be configured, by using VERIPOS Quantum software, or by using the
LD8 WebUI. Quantum must be used if being used f or system monitoring. If Quantum is not available, system
conf iguration must be performed through the WebUI, which features a terminal application that can be used for
sending commands.
This section introduces the WebUI and details how to perform LD8 system configuration via both the terminal
commands and, where available, the WebUI. For configuration with Quantum please refer to the
4.1 WebUI Status
Once connected to the LD8 via
and the WebUI has been loaded, the user will be presented with the
LD8 WebUI
Home > Status
page. This page displays inf ormation relating to the status and behaviour of the
system. To gain access to any other pages or f unctionality it is necessary to use the
Login
option, found in the
top right-hand corner of the page. To login to the system locate the LD8 serial number, which typically starts with
'NMPL' and can be f ound on the underside of the unit. When prompted, use the LD8 serial number as the
password and click
Log In
.
NOTE
The LD8 will be supplied with either the WebUI or Quantum. If the WebUI is required but missing
please contact VERIPOS.