Table 9 Nonport side LED patterns during normal operation (continued)
Recommended action
Status of hardware
LED color
LED name
NOTE:
When the switch is first
powered on the power supply
status LED will show amber until
POST has completed.
Do the following:
Fan assembly is not receiving
power.
No light
Fan status
•
Verify the fan FRU is seated.
•
Verify the switch is on.
No action required.
Fan assembly is operating
normally.
Steady green
Do the following:
Fan fault for one of the following
reasons:
Steady amber (for
more than five
seconds)
•
Verify the fan FRU is enabled (use
the
fanenable
command).
•
One or more of the fans in the
fan assembly has failed.
•
Replace the fan FRU.
•
The fan FRU was disabled by
the user.
NOTE:
When the switch is first
powered on, the fan status LED will
show amber until POST has
completed.
Port side LED activity for the Encryption SAN Switch
describes LEDs and recommended actions.
Table 10 Encryption SAN Switch and FRU LEDs
Recommended action
Status of hardware
LED color
LED name
No action required.
System is on and functioning
properly
No light
System status
(Attention)
Do the following:
Indicates one of the following:
Steady amber for more
than 5 seconds
•
Verify that the fan FRU and power
supply FRU are seated correctly.
•
Fan FRU or power supply FRU
is faulty.
•
•
Boot has failed.
Replace the fan FRU or power
supply FRU.
•
System is faulty.
1.
Connect a serial cable to the
system.
NOTE:
This LED displays
steady amber during POST, which
is normal and does not indicate a
fault.
2.
Reboot the system.
3.
Check the failure indicated on the
system console.
4.
Contact your service provider.
Verify that the system is powered on
(power supply switches to 1), the
System is off or there is an
internal power supply failure.
No light
Power status
power cables are attached, and the
power source is live.
If the system power LED is not green,
the unit may be faulty. Contact your
service provider.
No action required.
System is on and power supplies
are functioning properly.
Steady green
Port side LED activity for the Encryption SAN Switch