background image

2

Introduction  . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  3

The Manual  . . . . . . . . . . . . . . . . . . . . . . . . . . .  3

Production and System Numbers  . . . . . . . . . .  3

Unauthorized Replacement Parts  . . . . . . . . . .  3

Before Attempting to Operate This System . . .  3

Hetronic System Components . . . . . . . . . . . . .  4

Receiver Standard Features . . . . . . . . . . .  4

Transmitter Standard Features . . . . . . . . .  4

System Overview . . . . . . . . . . . . . . . . . . . . . . .  4

Theory of Operation  . . . . . . . . . . . . . . . . .  4

MFS Transmission Technology . . . . . . . . .  4

H-Link Technology. . . . . . . . . . . . . . . . . . .  4

E-Stop Function. . . . . . . . . . . . . . . . . . . . .  4

Receiver Safe Mode . . . . . . . . . . . . . . . . .  5

Optional Cable Control  . . . . . . . . . . . . . . .  5

Safety. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  5

Safety Alerts. . . . . . . . . . . . . . . . . . . . . . . . . . .  5

Notations . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  5

Practices and Laws . . . . . . . . . . . . . . . . . . . . .  5

Required Operator Training . . . . . . . . . . . . . . .  5

Possible Sources of Danger  . . . . . . . . . . . . . .  5

Operation and Work Area Safety . . . . . . . . . . .  6

Protective Features . . . . . . . . . . . . . . . . . . . . .  6

To Stop In An Emergency  . . . . . . . . . . . . . . . .  6

Maintenance  . . . . . . . . . . . . . . . . . . . . . . . . . .  6

Receiver Installation  . . . . . . . . . . . . . . . . . . . . . .  6

Receiver Location  . . . . . . . . . . . . . . . . . . . . . .  6

Receiver Production Number. . . . . . . . . . . . . .  6

Mounting the Receiver . . . . . . . . . . . . . . . . . . .  6

Receiver Housing  . . . . . . . . . . . . . . . . . . .  7

External Antenna Installation . . . . . . . . . . . . . .  7

Standard Antenna Extension. . . . . . . . . . .  7

Top Mount Antenna Extension  . . . . . . . . .  7

Connect Electrical Wiring. . . . . . . . . . . . . . . . .  8

Quick-Disconnect Plug  . . . . . . . . . . . . . . .  8

Quick-Disconnect Plug Wire Terminations   8

Hand Held Transmitter . . . . . . . . . . . . . . . . . . . . .  8

Frequency and Address Settings. . . . . . . . . . .  8

DK Assignments  . . . . . . . . . . . . . . . . . . . . . . .  9

Test Procedures . . . . . . . . . . . . . . . . . . . . . . . . . .  9

Holding the Transmitter . . . . . . . . . . . . . . . . . .  9

Test the System . . . . . . . . . . . . . . . . . . . . . . .  10

Operation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  11

Visual Check  . . . . . . . . . . . . . . . . . . . . . . . . .  11

Start-Up Procedure  . . . . . . . . . . . . . . . . . . . .  11

Emergency Stop  . . . . . . . . . . . . . . . . . . . . . .  12

Safe Mode . . . . . . . . . . . . . . . . . . . . . . . . . . .  12

Proportional Control Switch . . . . . . . . . . . . . .  12

Transmitter Shutdown  . . . . . . . . . . . . . . . . . .  12

Switch Error Detect  . . . . . . . . . . . . . . . . . . . .  12

LED Description . . . . . . . . . . . . . . . . . . . . . . .  12

Programmable Features  . . . . . . . . . . . . . . . .  12

Safety Features . . . . . . . . . . . . . . . . . . . . . . .  12

Interlocking Functions . . . . . . . . . . . . . . .  12

Low Voltage Warning Time  . . . . . . . . . . .  12

Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . .  13

Changing the Battery . . . . . . . . . . . . . . . . . . .  13

Battery Disposal. . . . . . . . . . . . . . . . . . . . . . .  13

Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . .  14

Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . .  15

Installation and Safety Test Data Sheet . . . . . .  16

Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  17

AWG - Metric Conversion Chart  . . . . . . . . . . . .  17

Abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . .  18

Warranty  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  19

TABLE OF CONTENTS

PRELIMINAR

Y COPY

Summary of Contents for HH-L-MFSHL TS7P

Page 1: ...r Avenue Halton Hills Ontario L7G 4X4 1 800 816 4459 Fax 1 905 702 0501 2005 Hetronic Inc All rights reserved No part of this publication may be reproduced transmitted transcribed stored in a retrieva...

Page 2: ...er 6 Receiver Housing 7 External Antenna Installation 7 Standard Antenna Extension 7 Top Mount Antenna Extension 7 Connect Electrical Wiring 8 Quick Disconnect Plug 8 Quick Disconnect Plug Wire Termin...

Page 3: ...arising out of the use of unauthorized replacement parts BEFORE ATTEMPTING TO OPERATE THIS SYSTEM 1 Make sure all installation has been properly completed 2 Understand all safety precautions provided...

Page 4: ...ess code This code allows the operation of multiple systems in the same general vicinity The receiver only accepts commands from the transmitter with the same address code MFS Transmission Technology...

Page 5: ...pment PRACTICES AND LAWS Practice usual and customary safe working precautions for the benefit of yourself and others Understand and follow all safety messages Be alert to unsafe conditions and the po...

Page 6: ...e gases or liquids Receiver must be protected from ambient temperatures outside the range of 18 to 158 F 25 to 75 C Receiver Production Number Locate the Hetronic Production number decal on the receiv...

Page 7: ...g 4 Insert the mounting screws through the holes in the housing block and tighten into the mounting surface 5 Bundle any excess antenna cable and secure with tie wraps or equivalent IMPORTANT DO NOT r...

Page 8: ...system using the new H Link wireless technology These are preset at the factory and are password protected Refer to the HH MFSHL H Link Programming Manual for more details IMPORTANT The Address and F...

Page 9: ...P DK9 S0 S t o p S t o p DK1 DK2 DK3 DK4 DK5 DK6 DK7 DK8 DK9 DK10 DK11 DK12 DK13 DK14 S1 S2 S3 S4 S5 S6 S7 HH L MFSHL TS7P S t o p S t o p S0 TEST PROCEDURES WARNING FAILURE TO FOLLOW INSTRUCTIONS cou...

Page 10: ...cates that the E Stop contact is open crane machine motions will NOT operate The LED on the receiver should flash yellow 5 Activate the motion toggle switches There should be NO movement of the crane...

Page 11: ...that the transmitter batteries are fully charged and inserted into the transmitter handle If any control is NOT in the Off neutral position when the battery is inserted the transmitter will not turn...

Page 12: ...a switch is active when the batteries are inserted the unit will go into an error state The red LED will come on and stay on until the active switch is turned off LED DESCRIPTION Transmit Mode Green...

Page 13: ...sposed of with typical refuse Contact a professional hazardous waste disposal service MAINTENANCE WARNING The transmitter will switch to the EMERGENCY STOP condition after the set amount of time expir...

Page 14: ...fter normal start up procedure E Stop switch engaged Pull out E Stop switch Batteries fully discharged Check batteries to ensure a full charge Replace with new batteries if necessary No power to the r...

Page 15: ...AA batteries Operation time Up to 500 hours Functions E Stop pushbutton 6 motion toggle switches Proportional grey code trigger switch Antenna Internal HH L MFSHL TS7P TRANSMITTER Weight 1 3 lbs 590g...

Page 16: ...operator is responsible for understanding and following all safety precautions in this and other applicable operator manuals INSTALLATION AND SAFETY TEST DATA Crane machine Data Manufacturer Model Num...

Page 17: ...the crane machine controls Maintained control The function activates when the control is placed in the ON position The function stops when the control is placed in the OFF position Momentary control T...

Page 18: ...c Millisecond MHz Megahertz MOV Metal Oxide Varistor type of surge suppressor mW Milliwatt NiCd Nickel Cadmium NiMH Nickel Metal Hydride PLC Programmable logic controller PLL Phased locked loop PTO Pr...

Page 19: ...any Company supplied items or materials List prices or discounts are subject to change without notice Quoted prices will be honored for a period of 90 days from the date of the written quotation unles...

Reviews: