6
Assembly, Operation & Maintenance Instructions
PIN CODE: 0845CR-0069
Barbeque
FORCE
TM
FURNACE
TM
Barbeque only
LENGTH
(mm)
WIDTH
(mm)
HEIGHT
(mm)
LENGTH
(mm)
WIDTH
(mm)
HEIGHT
(mm)
1170
515
410
1310
515
410
Barbeque and
stand
1170
750
1170
1310
750
1170
Air is admitted at the underside of the combustion chamber (two 35 mm x 20 mm gaps
between the fat tray and the chamber through an oval hole 75 mm x 135 mm in size).
Exhaust gases are emitted around the edge of the plates (6 mm gap) and through a 275
mm x 40 mm slot in the rear of the hood. When using an open grill, aeration also takes
place through the slots of the grill. Burner aeration 17.8 mm x 5 mm both sides.
APPLIANCE DETAILS
Note: The size of the injector diameter is stamped on one of the hexagon faces (e.g. ‘165’ for Ø1.65 mm injector).
MODEL
DESIGNATION
DESTINATION COUNTRIES
HEAT INPUT
BURNERS
INJECTOR
SIZE
GAS
CATEGORY
GAS TYPE
FORCE
TM
BE, FR, IT, LU, IE, GB, GR, PT, ES , CY, CZ,
LT, SK, CH, SI ,LV
2x3.9kW
2
φ
0.95mm
I 3+(28~30/37)
Butane at (28~30) mbar/ Propane at 37 mbar
LU, NL, DK, FI, SE, CY.CZ, EE, LT, MT, SK,
SI, BG, IS, NO, TR, HR, RO, IT, HU, LV
2x3.9kW
2
φ
0.95mm
I 3B/P(30)
Butane, Propane and their mixtures at 30mbar
AT, DE, CH, LU, SK
2x3.9kW
2
φ
0.83mm
I 3B/P(50)
Butane, Propane and their mixtures at 50mbar
FURNACE
TM
BE, FR, IT, LU, IE, GB, GR, PT, ES , CY, CZ,
LT, SK, CH, SI ,LV
3x3.2kW
3
φ
0.85mm
I 3+(28~30/37)
Butane at (28~30) mbar/ Propane at 37 mbar
LU, NL, DK, FI, SE, CY.CZ, EE, LT, MT, SK,
SI, BG, IS, NO, TR, HR, RO, IT, HU, LV
3x3.2kW
3
φ
0.85mm
I 3B/P(30)
Butane, Propane and their mixtures at 30mbar
AT, DE, CH, LU, SK
3x3.2kW
3
φ
0.74mm
I 3B/P(50)