LOCATION AND INSTALLATION/VENTILATION
(CONTINUED)
RECOMMENDED
GAS SHUT-OFF
VALVE LOCATION
G
ELECTRICAL SUPPLY LOCATION
FINISHED
FLOOR
VENT HOOD
E
COMBUSTIBLE
MATERIALS
MIN. CLEARANCE
TO NEAREST
COMBUSTIBLE
SIDE SURFACE
W
V
INSTALLATION CLEARANCES 30” WITH LOW BACKGUARD
FRONT VIEW
18" [45.7]
MIN.
18"
[45.7]
7"
[17.8]
12"
[30.5]
1-1/2"
[3.8]
4"
[10.2]
11"
[27.9]
2-1/2"
[6.4]
RANGE MODEL
W
V
(MIN)
KRD304
30” [76.2]
30” [76.2]
NOTES:
* SHADED AREAS INDICATE WHERE COMBUSTIBLE MATERIALS ARE NOT ALLOWED.
* APPLIANCE TOP MUST BE LEVEL OR HIGHER THAN THE ADJACENT COUNTERTOP SURFACES.
* "G" IS GAS CONNECTION ZONE ON REAR WALL. MOUNT SHUT-OFF VALVE AS HIGH AS POSSIBLE
IN THIS ZONE FOR EASY ACCESS WHEN RANGE IS INSTALLED.
* "E" IS ELECTRICAL SUPPLY ZONE.
* "W" IS APPLIANCE OPENING.
* "V" IS MIN. CLEARANCE TO REQUIRED VENTILATION HOOD.