LOCATION AND INSTALLATION/VENTILATION
(CONTINUED)
NOTES:
* SHADED AREAS INDICATE WHERE COMBUSTIBLE MATERIALS ARE NOT ALLOWED.
* APPLIANCE TOP MUST BE LEVEL OR HIGHER THAN THE ADJACENT COUNTERTOP SURFACES.
* "G" IS GAS CONNECTION ZONE ON REAR WALL. MOUNT SHUT-OFF VALVE AS HIGH AS POSSIBLE
IN THIS ZONE FOR EASY ACCESS WHEN RANGE IS INSTALLED.
* "E" IS ELECTRICAL SUPPLY ZONE.
* "W" IS APPLIANCE OPENING.
* "V" IS MIN. CLEARANCE TO REQUIRED VENTILATION HOOD.
DIMENSIONS IN BRACKETS [ ] ARE IN CM.
18” [45.7]
MIN.
RECOMMENDED
GAS SHUT-OFF
VALVE LOCATION
VENT HOOD
COMBUSTIBLE
MATERIALS
4”
[10.2]
11”
[27.9]
23”
[58.4]
7”
[17.8]
ELECTRICAL SUPPLY LOCATION
1-1/2”
[3.8]
12”
[30.5]
MIN. CLEARANCE
TO NEAREST
COMBUSTIBLE
SIDE SURFACE
FINISHED
FLOOR
[45.7]
18”
INSTALLATION CLEARANCES
WITH LOW BACKGUARD
FRONT VIEW
48"
W
V
E
G
RANGE MODEL
W
V
(MIN)
KRD485GD
48” [121.9]
30” [76.2]
KRD484GD
48” [121.9]
30” [76.2]