![Hess LED KIT VS.16 Instruction Manual Download Page 8](http://html1.mh-extra.com/html/hess/led-kit-vs-16/led-kit-vs-16_instruction-manual_2127403008.webp)
8
Hess GmbH Licht + Form
Lantwattenstrasse 22
78050 Villingen-Schwenningen
Germany
Tel. +49 7721 / 920-0
Fax +49 7721 / 920-250
[email protected]
www.hess.eu
W
e r
eser
ve the right
to m
ak
e t
ec
hnic
al
c
han
ge
s
WIELAND ST18/3 device plug system
Note:
Depending on the configuration ordered, there is a pre-
fitted WIELAND plug (male) with brown/red coding in the
LED KIT and in the “PROFESSIONAL” / “PROFESSIONAL
HP” version, this is assigned with (L I PSt I N). With many
standard luminaires (usually in the SKI version), a device
socket from ADELS with white coding or a device socket
from WIELAND with black coding is fitted on the supply
line and attached to the central protective conductor
connection. If no control line exists or is to be used on
the pole side, this white/black socket (female) can be
combined with the brown/red plug on the LED KIT pro-
vided that the PSt conductor is disconnected from the
plug on the LED KIT side. This should be clearly marked
on the WIELAND plug for inspections at a later date.
Alternatively, a WIELAND socket with red/brown coding
can be ordered as an accessory and fitted on the supply
line in place of the white socket, in which case the pro-
tective conductor must not be attached!
The PSt control
input of the LED KIT must never be connected with the
protective conductor.
In the “Basic” version, the central contact of the WIELAND
plug, which may be fitted on the LED KIT, is not assigned.
In this case, the supply line’s socket can be connected
just as it is.
General safety notices
• Assembly/maintenance and work on the electri-
cal supply may only be undertaken by an autho-
rised electrician (electrical installer, specialist) in
accordance with recognised electrical regulations.
• Access to the voltage supply should be sealed off at
all times. Only authorised staff have access to the
voltage supply.
• When working on live parts, these must be de-ener-
gised and secured so that they cannot be switched
back on again by mistake.
• Check covers, seals, lamp sockets for cracks and
wear and replace with original spare parts if necessa-
ry.
• Only use original parts for any repairs/mainte-
nance. Ensure that all protective devices are refit-
ted.
• Should the luminaires be modified at a later date,
the company which undertakes these modifica-
tions is considered the manufacturer.
• The electrical equipment should be checked on a
regular basis. Loose and damaged cables must be
replaced immediately.
Warranty and liability
The “General terms and conditions of sale and delive-
ry” of Hess apply. There are no grounds for warranty
and liability claims if these can be traced back to one
or more of the following causes:
• Unintended use
• Improper assembly and/or use and resultant
damage
• Failure to observe safety notices, specifications
and assembly instructions
• Structural modifications undertaken at a later
date
• Operation with defective and/or non-functional
safety or protective equipment
• Interventions performed incorrectly
• Catastrophes, impact of external objects and
force majeure
Copyright
Hess retains all copyrights to the entire documentati-
on. No part of these documents may be reproduced,
duplicated or transmitted in any form without the
express written permission of Hess.
Further details from the manufacturer
For more information about the respective compo-
nents, assemblies and products, consult the docu-
mentation provided by the relevant manufacturer.
Note
The diagrams provided in these assembly/opera-
ting instructions, depict
examples of variants and may vary from your
version.
L
N
L
N
T
1
L
N
P
St
L
N
L
N
PE
T
2
S
3
Contact
marking
SKII with
control phase
SKII w/o
control phase
SKI w/o
control phase
Occupancy
Type of
connector
Coding
female
Coding
male