6
Technical data
Note
If mains are frequently subject to peaks in vol-
tage, take additional relevant surge protection
measures as necessary.
Elect. connection Device plug
WIELAND ST17 3-pole
Dimensions
Ø 155/H272mm;
Weight
1,100g
Ingress protection
IP20
Ingress protection of luminaire
≥ IP43
Ambient temperature
-35....+35°C
Volume of lamp space
≥ 14dm³
Nominal voltage
220-240V AC 50Hz
2)
Power factor
> 0.9
Protection rating
II
Overvoltage protection
6KV (surge)
Nominal power [W]
Asym
Sym
HIGHPOWER
23-28
32-36
PROFESSIONAL
16-19
24-28
BASIC
16
24
Luminous flux with directional
optics [klm]
Asym
Sym
HIGHPOWER
2.5
constant
3.5
constant
PROFESSIONAL
1.8
constant
2.5
constant
BASIC
1.8
2.5
Colour rendering index (CRI)
> 80
Conformity
CE
Special equipment
TempSafe (TS)
overtemperature protection
Constant Flux (CF)
constant luminous flux over 50,000hr
AutomaticDimControl (ADC)
2)
LED KIT is basically suitable for use in systems where dimming is controlled by
reducing voltage and/or varying frequency and works independently of the voltage/
frequency conditions with a constant light output. We would recommend investigating
suitability for use on a case by case basis.
Please note details on the type plate!
AutomaticDimControl (ADC) setting
The LED KIT is equipped with an OSRAM Optotronic4DIM
or Philips XITANIUM LED operating device to suit your
project. Parameters for the dimming functionality and
dimming profile are set in the factory by means of
software programming as requested by the customer.
In order to set parameters for the ASTRODIM function
(automatic dimming, based on midnight), the Tdimon
and Tdimoff desired for the system and the desired
level of dimming (50% is standard) should be commu-
nicated with the order. The values set in the factory are
shown on a sticker located next to the type plate. The
parameter settings can only be changed using a specific
programming adapter and a PC with the corresponding
programming software.
Using the PSt input, the LED KIT can be added to an
existing control phase. If this is done, the existing con-
trol logic is detected automatically once switched on for
around 20min.
100%
dim
aus
T
dim
Level
ein
T
dim