11
Installation
Installation
Installation site
Installation site
Checklist before installing
The site must be
flat and horizontal.
The floor must have
minimum 160mm
depth of reinforced
concrete.
Surface load under
the posts must be
minimum 25N/
㎟
.
To maintain the warranty,
the lift is intended for
indoor installation
only. In the event that
it is installed outside it
should be protected from
snow and rain. Outdoor
installation makes the
warranty invalid.
Installation site
Ambient
temperature
10℃ to 50℃.
Do not operate
under freezing
conditions.
Vehicle access to
the lift must be
safe and easy.
There must be
a safe working
distance of
minimum 1m
between the lift
and the wall or any
fixed object.
To ensure that the
anchor is secure,
the hole for an
anchor bolt must
be more than 2/3
of the bolt length.
Skilled engineers
of Heshbon or its
sale representative
agency shall install
the lift, otherwise a
failure may occur.
Please contact
Heshbon
head office or
distributors for the
removal of lifts.
Summary of Contents for HL-32X
Page 10: ...7 Caution Sticker layout Caution Warning Danger Introduction Introduction...
Page 11: ...8 Heshbon Lift Capacity Heshbon logo Heshbon symbol Hand Foot Warning Introduction...
Page 22: ...19 MEMO Installation Installation...
Page 27: ...24 TROUBLE SHOOTING Maintenance Maintenance...
Page 28: ...25 Check list and periodic maintenance Maintenance Maintenance...
Page 30: ...27 Platform Link...
Page 31: ...28 Base...
Page 32: ...29 Cylinder...
Page 33: ...30 Control Panel...
Page 34: ...31 Hydraulic Circuit...
Page 35: ...32 Electric Circuit...