Fault reports and their corrections
10
69
No. Fault report
Cause of fault
Fault correction
017
HC-OUTSIDE SENSOR
Failure heating circuit outside
temperature sensor
▪
Check sensor, replace as
necessary
▪
Check plug, replace as necessary
▪
Check wiring incl. connections,
replace as necessary
▪
✆
- contracting party
018
SENSOR COLLECTOR
Failure solar collector temperature
sensor
▪
Check sensor, replace as
necessary
▪
Check plug, replace as necessary
▪
Check wiring incl. connections,
replace as necessary
▪
✆
- contracting party
019
SENSOR COLLECTOR
BACK FLOW
Failure solar collector back flow
temperature sensor
▪
Check sensor, replace as
necessary
▪
Check plug, replace as necessary
▪
Check wiring incl. connections,
replace as necessary
▪
✆
- contracting party
020
SENSOR SOLAR TANK 1
Failure solar tank temperature
sensor (hot water tank/buffer)
▪
Check sensor, replace as
necessary
▪
Check plug, replace as necessary
▪
Check wiring incl. connections,
replace as necessary
▪
✆
- contracting party
021
SENSOR SOLAR TANK 2
Failure solar tank temperature
sensor (hot water tank/buffer)
▪
Check sensor, replace as
necessary
▪
Check plug, replace as necessary
▪
Check wiring incl. connections,
replace as necessary
▪
✆
- contracting party
022
SENSOR SOLAR RES.
Failure reserve solar sensor
▪
Check sensor, replace as
necessary
▪
Check plug, replace as necessary
▪
Check wiring incl. connections,
replace as necessary
▪
✆
- contracting party
023
ADDITIONAL BOILER
SENSOR
Failure additional boiler sensor;
cable break; short-circuit; failure
connection
▪
Check sensor, replace as
necessary
▪
Check plug, replace as necessary
▪
Check wiring incl. connections,
replace as necessary
▪
✆
- contracting party
024
MODUL SENSOR
Failure temperature sensor of
modul; cable break; short-circuit;
failure connection
▪
Check sensor, replace as
necessary
▪
Check plug, replace as necessary
▪
Check wiring incl. connections,
replace as necessary
▪
✆
- contracting party
025
OVERHEAT BOILER
MAX
boiler temp. higher 92,5°C or.
104,5°C
▪
Check settings
▪
Check back flow mixer
▪
Check back flow pump
Summary of Contents for firematic PELLET 120
Page 1: ...OPERATING INSTRUCTIONS Wood chips pellets heating system firematic PELLET 120 201 ...
Page 84: ...15 Annex 84 15 ANNEX 15 1 Additional boiler module Hydraulic recommendation 1 ...
Page 85: ...Annex 15 85 Hydraulic recommendation 2 ...
Page 86: ...15 Annex 86 15 2 Solar module Program 1 ...
Page 87: ...Annex 15 87 Program 2 ...
Page 88: ...15 Annex 88 Program 3 ...
Page 89: ...Annex 15 89 Program 4 ...
Page 90: ...15 Annex 90 Program 5 ...
Page 91: ...Annex 15 91 Program 6 ...
Page 92: ...16 Notes 92 16 NOTES ...
Page 93: ...Notes 16 93 ...