Fault Reports and their correction
9
Betriebsanleitung_firematic_20-301_Touch_Englisch V1.2
55
Fault reporting on the display
Possible cause?
Suggestions for rectifying
F: TEMP. CONTROL
Temperature monitoring in the
storage room has risen above
the
maximum
permissible
temperature.
Sensor in the storage room has
risen above the permissible
range.
•
Switch off the system
•
Control storage room
•
If necessary, call fire fighters
FAULT 68
F: STL
Pellet boiler temperature has
exceeded
the
permissible
maximum temperature
•
Contact
your
specialist
installer.
FAULT 69
F: LAMBDA FUEL
To high residual oxygen
•
Check heating values
FAULT 70
F: LAMBDA SENSOR
Lambda probe calibration error
•
Contact
your
specialist
installer.
FAULT 71
F: CAN FAULT
Fault in CAN Bus
•
Contact
your
specialist
installer.
FAULT 72
F: LAMBDA CALIBRATION
Lambda probe calibration error
•
Contact
your
specialist
installer.
FAULT 73
F: EMPTY ASH
Ash pans need to be emptied
•
Empty the ash pans
FAULT 74
F: ASCHENBEH. VOLL
Ash pans are full and need to be
emptied
•
Empty the ash pans
FAULT 75
F: FUEL
FAULT 76
Error „fire out“ has occured
within 2h again.
•
see error 66
F: ADDITIONAL INPUT
Additional input (for example CO
detector) has been activated
Check system pressure
•
-
FAULT 77
F: NIVEAU LEVEL
Niveau
sensor
has
been
activated
•
-
FAULT 78
F: BARRIER LEVEL
Sensor in the insertion screw
channel reports that no material
is available
•
To little material in the
insertion
•
Control
fuel
supply
and
settings
FAULT 79
F: MP ROOM DISCHARGE
Motor protection for feed screw
motor activated
•
Contact
your
specialist
installer.
FAULT 80
F: SPEED ID-FAN
Fault in the device for monitoring
the speed of the induced-draught
fan
•
Contact
your
specialist
installer.
FAULT 81
F: GRATE CLEANING 1
Fault affecting grate cleaning
Limit switch is always in the
same position
Drive motor for grate cleaning
defective
Drive linkage defective or loose
Combustion grate sensor out of
position
•
Contact
your
specialist
installer.
FAULT 82
F: GRATE CLEANING 2
Fault affecting grate cleaning
Grate will not close
Grate is blocked
Grate linkage defective or loose
•
Contact
your
specialist
installer.
FAULT 83