Now you can check the RF distance, go to the room which must be regulated. Put your thermostat on the final position
(On the wall or table...), then put the thermostat in the comfort mode (setting temperature position 37 °C). Close the
door and go to the receiver to check if the new status of the thermostat has received. (The heating is generally showed
by a Red LED on the receiver). Now return to the thermostat and switch it off.
Check the receiver again, if it’s also switched off (The red LED must be turned off).
If the RF signal is received correctly, adjust your setting temperature as you want. If the RF signal isn’t received correctly,
check the installation (Receiver position, distance...) or restart the
« rF ini »
rules to be sure. To make the installation
easier, it will be better to have the thermostat closer to the receiver during the configuration mode. (A minimal distance
of > 1meter must be kept).
Case of central
:
The link is done with central.
Starting
The thermostat is now ready to work. The default working mode is automaticly programed with the standard built-in
programm
„P1“
.
•
Monday to Friday
•
Saturday to Sunday
Note:
You can customise your program as you want. See the next part
“Working mode definition”
for more
explanations.
Note:
At any time, when the backlight is extinct, press the
(OK)
key to lit-up the backlight and then press
another time the
(OK)
key to show the current setting temperature.
actual value
actual status
Program