21UD
33
5-10
.
Setting the stop at the PLAN=ACTUAL Command
【
F
1】
①
Press [F1] key, and Stop at the PLAN=ACTUAL setting screen appears.
If there is no need to change the setting contents, press [ENT] key to return to the
Command selection screen.
1
0
←Display about 0.75seconds
Press [F1]key,display”10”
↓
0
←present date
②
Input optional setting value
1
←input date
③
Here, press [ENT] to set the stop at the PLAN=ACTUAL, and Command selection screen
comes back.
If you have inadvertently press a wrong type No, press [CLR] key to get back to the
status of
①
or overwrite the correct No to modify.
*When
“
No
”
for Tact reserve function is set in Function setting
The stop at the TARGET=PLAN function is only effective when type included
“
TARGET
”
are set in the
《
5-1. Type
》
setting and Tact reserve function are not used.
When
“
Yes
”
for Tact reserve function is set in Function setting
The stop at the TARGET=PLAN function is effective no relation of type setting.
Target value of present reserve No. is intended to be compared
Function settings
Setting the stop at the PLAN=TARGET
0
→
Not stop PLAN value at the PLAN=TARGET
1
→
Stop PLAN value at the PLAN=TARGET