Select XLS
Herschel Easy-fix mounting system
Assembly Kit
Please check the enclosed assembly kit consists of:
1 x mounting bracket,
4x screws,
4x rawlplugs
Preparation
The centre of the mounting bracket will be the centre point of the panel when mounted (note, the mounting fixings
on the rear of the panel are offset, so measure from the centre of the panel to the edge of the panel to determine
the mounting position). For vertical (portrait) mounting position
“A”
will be the top of the mounting bracket. For
horizontal (landscape) mounting position
“B”
will be the top of the mounting bracket.
Step 1
Use a spirit level to ensure the bracket is level and mark
the position for drilling in each of the small holes in the
four corners of the mounting bracket (figures 1 & 2).
Step 2
Drill holes using a 8mm drill. Insert the supplied
rawlplugs (see figure 3). If mounting on to a cavity wall
or ceiling you will need appropriate fixings (not
supplied).
Step 3
Screw the mounting bracket to the wall using the
supplied screws (figure 4).
Step 4
Fit the panel to the wall by locating all four mounting
fixings on the rear of the panel into the wide
openings on the mounting bracket. Once in position
the panel should be moved to the right and then
down and to the right again to its secure position
(portrait mounting) or down, then left and then down
again (landscape mounting) (fig 5 & 6).
Step 5 (Mirrors & Glass panels only)
Unscrew the four distance pieces (in each corner) on the rear of the heater panel so that the panel is held tightly in
its mounting on the wall or ceiling and cannot be moved. If mounting to a ceiling it is extremely important that the
panel is locked in this secure position. Ensure the power lead is free from any obstruction from the panel.
Removal
Herschel Easy-fix is designed to be secure to avoid accidental dismounting or tampering with the panel. To
dismount the panel, screw the four distance pieces back in and move the panel to the left, then up and over to
the left again (portrait mounting) or up, then to the right and then up again (landscape mounting).
NOTE:
If mounting larger panels (600w upwards) to a ceiling, use suitably rated fixing screws/mechanism for
the weight of the panel. Use the additional 2 fixing holes on the Easy-Fix mounting plate and fix to a joist
wherever possible. 2 people may be needed to mount the larger panels.
IMPORTANT
Glass and mirror panels are not designed for ceiling
mounting and there is a risk of overheating and glass
shattering or shortening of the panel lifespan. Do not
ceiling mount glass or mirror panels.