T1 (Gen 3) WIRELESS THERMOSTAT
Program Mode
The T1 has a 7 x 1 day timer (Monday to Sunday) with
4 periods per day. Set Period 1 as the temperature
for the morning. Period 2 is the fallback temperature
for the daytime. Period 3 is the temperature required
for the evening and period 4 is the overnight
temperature.
Unlike conventional heating, Herschel Far infrared
directly heats
the room (the “Thermal Mass”). For
areas in frequent use it is more economical to avoid
temperatures dropping too low as the heater will need
to be on for a much longer period to restore
temperatures. We recommend overnight setback
temperatures of no lower than 14°C and daytime
temperatures of 16°C and above.
To select Program Mode press MENU until PRG is
displayed as the mode. The schedule will then operate
until another mode is selected.
To set the 7 days program
The default program you will receive with your T1 is:
To alter this schedule:
•
Press the PRG button for 3 seconds to start the 7
x 1 day program setting. The First period of the
First day is selected.
All days
Period 1
0600 20
℃
Period 2
0900 16
℃
Period 3
16:00 20
℃
Period 4
23:00 16
℃
•
Press the Up or Down button to change the time of
the first period of the day’s program.
•
Press PRG again to move to the temperature
setting of the first period and use the Up and Down
buttons to adjust the temperature.
•
Press PRG again to move to the second period of
the first day’s program. Repeat the above
procedure to finish setting the other periods of the
first day’s program.
•
Press PRG again to move to the first period of the
second day.
•
Once setup is complete, press Return to get back
to the main display.
Temperature can always be overridden manually by
pressing the Up and Down buttons. The temperature
will remain at this setting until the next programmed
change occurs. For example, using the default
schedule in the previous table, if it was 18:00 on a
Monday the thermostat would be set to 20°C. If you
wished to increase the temperature to 21°C, press the
Up button to increase temperature to 21°C. The
thermostat would then retain this setting until 23:00
when the period 4 schedule would reduce the set
temperature to 16°C.
Parameter Settings
The T1 has several special operating parameters you
can set, these are:
Temperature Calibration
to adjust the unit to
compensate temperature up or down by up to 8°C. For
example if you have another control in the room which