background image

 

The product complies with Safety Standards EN60335-2-30, RoHS, EMC EN 50336 & EN 62233 & Ecodesign requirements 

for local space heaters. These cover the essential requirements of EEC Directives 2006/42/EC, 2011/65/EC, 2004/108/EC 
and 2009/125/EC. 
Original instructions covering COLORADO 2500R produced 012019 onwards. 

 

HERSCHEL COLORADO 2500 Watts 

Ceiling or Wall-mounted Infrared Heaters 

 

INSTALLATION & OPERATING INSTRUCTIONS 

 

 

 

 

TECHNICAL INFORMATION:

 

 

 

Rated Power: 
Heating Element:

 

Reflector: 
Dimensions:

  

Remote control:

  

 
Warm-up time:

  

Useful wavelength range:

  

Weight:

  

Warranty: 
Protection:

  

 

2500W at 220-240V 
Ultra long life Carbon heating lamp (up to 10,000 hours) 
Mirror Aluminium (98% reflection preventing rearward heat loss) 
879 x 195.3 x 84.7 mm 
4 power levels (25% power increments) & 0-24 hour timer (24 x 1 hour 
increments) 
5-10 seconds 
2 - 5

μm

 

3kg 
2 Years (excludes lamp & remote control) 
IP55

 

 

 

ELECTRICAL EQUIPMENT: 

Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. 

 

 

 
IMPORTANT NOTICE TO PURCHASER: 

Before utilizing the product, you should determine the suitability of the product for its intended use. HERSCHEL INFRARED LTD 
expressly disclaims the implied warranties and conditions of merchantability and fitness for a particular purpose. In no case shall 
HERSCHEL INFRARED LTD be liable under any legal theory, including but not limited to contract or strict liability, for any direct, 
indirect special, incidental or consequential damages resulting from product use.

 

 

Summary of Contents for COLORADO 2500

Page 1: ...or Aluminium 98 reflection preventing rearward heat loss 879 x 195 3 x 84 7 mm 4 power levels 25 power increments 0 24 hour timer 24 x 1 hour increments 5 10 seconds 2 5μm 3kg 2 Years excludes lamp remote control IP55 ELECTRICAL EQUIPMENT Waste electrical products should not be disposed of with household waste Please recycle where facilities exist IMPORTANT NOTICE TO PURCHASER Before utilizing the...

Page 2: ...F during operation Contact with the heater during operation may cause severe burns Do not touch the heater during or for 10 minutes after operation 7 DO NOT use the heater if the power cord is damaged This must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard 8 DO NOT use the heater to ignite materials DO NOT operate in locations containin...

Page 3: ...d the GREEN YELLOW wire to EARTH E MOUNTING POSITION The recommended installation height of the COLORADO is 1 8m 2 4m 71 95 from the floor The lower the heater is positioned the more intense the heat Under no circumstances is the COLORADO to be installed at less than 1 8m 71 from the floor Consideration should be given to any temporary or occasional additions such as stages or platforms and adjust...

Page 4: ...all the appliance This heater is not intended for ceiling recessed installation Do not install pointing directly downwards The identification mark and model reference should be visible after installation The COLORADO must not be attached facing or close to any combustible material eg wood or PVC cladding fascia or soffit or other materials that could blow onto the heater The fixed wiring insulatio...

Page 5: ...it is advisable to warm the heater for 10 20 minutes to dry the unit and prevent staining The lamp used in the Herschel Colorado is Ultra long life up to 10 000 hours Changing the lamp should only be carried out by suitably qualified personnel using the instructions available on Herschel s website TROUBLESHOOTING MODEL 2500R E1 Error on Display Control unit overheat Check installation clearances L...