background image

Operating and Installation Instructions 

 

 

 

herose.com 

Page 15 

 

8.  Other Applicable Documents 

Pressure equipment directive 2014/68/EU 

 

For installation in Germany 

Druckgeräteverordnung (14.ProdSV) [

Pressure Equipment Regulation

Betriebssicherheitsverordnung (BetrSichV) [

German Health and Safety 

Regulations

Technical Rules for Operating Safety (TRBS) 

 

Other EU Countries 

Relevant national regulations 

9.  Warranty 

The scope and period of warranty is stated in the current version of the "General 
Terms and Conditions of Business of HEROSE GMBH" which is valid at the time 
of  delivery,  or in  deviation  from  these,  in  the  purchase contract.  No  warranty  can 
be  accepted  for  damage  which  is  due  to  incorrect  handling  or  failure  to  observe 
these Operating and Installation Instructions, regulations by the employers' liability 
insurance associations for industrial health and safety, or EN, DIN, VDE standards 
and other rules. 
Damage  which  occurs  during  operation  due  to  conditions  of  use  which  deviate 
from the conditions of use specified in the data sheet or in other agreements are 
also not subject to warranty. Claims which exceed those covered by the warranty 
are excluded. There is no entitlement to the supply of replacements. Maintenance 
work,  installation  of  third  party  components,  modifications  to  the  construction  as 
well  as  natural  wear  and  tear  are  excluded  from  the  warranty.  Any  transport 
damage should not be reported to us, but rather to the responsible goods handling 
department of the railway or carrier, as otherwise claims for compensation against 
these companies may become invalid. 

 

 

Summary of Contents for 4186 Series

Page 1: ...herose com HEROSE GMBH ARMATUREN UND METALLE Original Operating and Installation Instructions Combi Regulator 4186 E N...

Page 2: ...UREN UND METALLE Elly Heuss Knapp Stra e 12 23843 Bad Oldesloe Tel 04531 509 0 Fax 04531 509 120 Web http www herose com E mail info herose com 5th edition 07 2016 HEROSE 2015 Disclosure and reproduct...

Page 3: ...orage 8 5 Technical Data 8 5 1 Purpose and Field of Use 8 5 2 Function 9 5 2 1 Pressure Build up Function 9 5 2 2 Pressure Build up Economizer Function 9 5 2 3 Safety Function 9 5 3 Product Data 9 5 3...

Page 4: ...aintenance 12 7 1 Commissioning 12 7 2 Adjusting the Nominal Working Pressure 12 7 3 Maintenance and Repair of the Valve 14 7 4 Dismantling the Valve 14 8 Other Applicable Documents 15 9 Warranty 15 1...

Page 5: ...ting and Installation Instructions herose com Page 4 1 Schematic Illustration of Combi Regulator 1 1 Illustration 4186 1 A B C Einstellschraube SW 27 Kontermutter SW 30 Locknut SW 30 Set point screw S...

Page 6: ...Operating and Installation Instructions herose com Page 5 1 2 Illustration 4186 3 Locknut SW 19 Set point screw SW 14...

Page 7: ...cations and improvements at any time The use of these Operating Instructions assumes that the user is qualified as described under section 2 4 Qualified personnel The operating personnel must be instr...

Page 8: ...ety Information The safety and warning information is structured as follows Source of hazard Results if the hazard is ignored Measures to prevent the hazard and avoid injuries Hazardous Media Poisonin...

Page 9: ...an Health and Safety Regulations and its TRBS Technical Rules for Operating Safety 4 Transport and Storage 4 1 Transport Transport temperature 20 C to 65 C Protect against external effects shock impac...

Page 10: ...5 2 Function 5 2 1 Pressure Build up Function If the pressure in the vessel is less than the nominal working pressure which is set the Combi Regulator opens in order to restore the nominal working pr...

Page 11: ...Response pressure 0 5 bar above working pressure Working pressure ranges 1 12bar 6 24bar 16 38bar 2 10bar 8 22bar 20 38bar 6 Installation 6 1 Handling Prior to Installation of the Regulator If the va...

Page 12: ...2 6 3 Basic Installation Notes Tension free installation must be ensured The valve must not serve as a fixed point it is supported by the piping system The connecting piping must be connected without...

Page 13: ...sition must be checked against the plan of the piping system The BetrSichV German Health and Safety Regulations and its TRBS Technical Rules for Operating Safety must be observed Residues in the pipin...

Page 14: ...Table 1 or Adjustment diagram 1 If pressure gauges are used in the system it is recommended that the Combi Regulator is adjusted according to the values indicated on the pressure gauge If the system...

Page 15: ...pring cover During repairs maintenance and cleaning the condensation drain hole in the spring cover must be visually inspected regularly and any dirt must be removed Repairs may only be performed by H...

Page 16: ...handling or failure to observe these Operating and Installation Instructions regulations by the employers liability insurance associations for industrial health and safety or EN DIN VDE standards and...

Page 17: ...Operating and Installation Instructions herose com Page 16...

Page 18: ...Operating and Installation Instructions herose com Page 17 10 Notes...

Reviews: