4.3 

Intended use 

Ball valves are used to allow or block the flow of media under pressure. Ball valves are intended 
exclusively for installation in pipework systems with connections of the same pressure rating and 
corresponding connection or between flanges of the same pressure rating and identical flange connection. 
The closing direction is clockwise. 

4.4 

Operating data 

Valve 

Rated 
pressure 

Temperature 

Max. operating pressure 

15C01 

PN 50 

-196 °C to +65 °C 

50 bar 

4.5 

Media 

Gases, cryogenic liquefied gases and their gas mixtures, such as: 

Name 

Argon 
Chlorotrifluoromethane 
Nitrous oxide 
Ethane 
Ethylene 
Helium 
Carbon dioxide 
Carbon monoxide 
Krypton 
Air 
Methane 
Neon 
Oxygen 
Nitrogen 
Trifluoromethane 
Hydrogen 
Xenon 

Summary of Contents for 15C01

Page 1: ...HEROSE GMBH ARMATUREN UND METALLE Operating instructions 3 piece ball valve...

Page 2: ......

Page 3: ...ermany Phone 49 4531 509 0 Fax 49 4531 509 120 E mail info herose com Web www herose com 1st issue 06 2019 The transmission or duplication of this document and the use or communication of its content...

Page 4: ...I Phone 49 4531 509 0 Table of contents 1 About these instructions 1 2 Safety 1 3 Transport and storage 4 4 Description of the ball valve 4 5 Assembly 7 6 Operation 9 7 Maintenance and service 9 8 Dis...

Page 5: ...operating instructions The ball valve is suitable for the media listed in these operating instructions see section 4 5 Media Operating conditions and applications deviating from these require the appr...

Page 6: ...dia Safety gloves Eye protection Ear protection Wear the specified personal protective equipment for all work on the ball valve 2 5 Additional equipment and spare parts Additional equipment and spare...

Page 7: ...NOTICE Impermissible stresses arising from operating conditions and extensions added structures Leakage or rupture of the valve body Provide suitable support Additional loads such as traffic wind or...

Page 8: ...f condensation Adhere to a storage temperature range of 20 C to 65 C 4 Description of the ball valve Refer to the respective catalogue page for further detailed information 4 1 Structure Design Non au...

Page 9: ...n or between flanges of the same pressure rating and identical flange connection The closing direction is clockwise 4 4 Operating data Valve Rated pressure Temperature Max operating pressure 15C01 PN...

Page 10: ...his case a technical service life may be assumed in accordance with the underlying product standards e g EN1626 for shut off valves and EN ISO 4126 1 for safety valves The technical service life can b...

Page 11: ...s or covers before assembly Inspect the valve for dirt and damage DO NOT install a damaged or dirty valve Avoid damaging the connections The sealing surfaces must remain clean and intact Seal the valv...

Page 12: ...e side parts Do not damage the seal Mount the bolts Tighten the bolts to the specified tightening torque in a criss cross pattern Direction of rotation clockwise Assembly sequence for the bolts Nomina...

Page 13: ...e operating conditions The recommendations for the functional checking of the valves are to be taken from section 7 2 1 Inspection and maintenance intervals in these operating instructions 7 2 1 Inspe...

Page 14: ...antity dispatch and delivery address desired method of dispatch 7 5 Returns complaints Use the Service form in case of returns complaints Contact in case of service Herose com Service Product service...

Reviews: