Match the corresponding active (brown),
neutral (blue) and ground wire (yellow-
green) and tighten up screws to make sure
power is properly connected.
•
Insert plenum mounting bracket
through the ceiling to base. Pay attention
as the “C” hook must match the
corresponding “C” area on the base.
Finally fasten.
•
Insert 4xM8 bolts, washers, spring
washer and metal plate via mounting
frame to the base.
Important: ensure the tightening torque
from 12 to 14 N.m
•
Tie the room temperature sensor onto
the rib of mounting bracket.
•
Plug the connectors on the plenum to
the base. Push plenum into outlet duct and
fasten 4xM4 screw on the bottom. Finally
add the filters to the sides of the plenum.