background image

For more detail information, please check out www.hernest.com
It will be our pleasure to have your visit.

 2) Set the thermostatic mixer temperature above 40 

, but still no hot water

a.the temperature of hot water supply does not reach above 55 

, solution: increase the temperature of hot water 

source to ensure to meet the constant temperature conditions

.

b.the water pressure of hot water supply fails to reach the constant temperature condition (the water pressure is not 
enough, which is commonly used by solar rooftop users or high-rise households)
Solution: for users with normal water pressure of cold water supply, it is recommended to replace the solar water 
heater with other water storage water heaters, and if the water pressure cannot meet the requirements of constant 
temperature mixer, it is suggested to add booster pump. The hot water temperature of the water heater is generally 
higher than 100 

, and the hot water temperature exceeds the limit temperature of the thermostatic mixer (The hot 

water temperature of the thermostatic faucet is between 55 

 - 85 

), so that the thermostatic mixer cannot work 

normally.

The gas water heater is not on fire or stops for a while:the water temperature is fluctuated. The main reason is that 
the  water heater sets a default value to meet its own requirements, so the water flow and temperature are not 

enough. 

Solution: adjust the default value of the gas water heater factory setting to the conditions required by the thermo

-

static mixer water temperature can be used.
The electric water heater with the outlet water temperature of the thermostatic mixer is low. the main reason is that 
the temperature of the heater is generally set at about 50 

 when it leaves the factory, so the hot water for the 

thermostatic mixer will be low, solution: reset the hot water outlet temperature of the heater, and it is recommended 
to set it at about 60 

.

 There is water dripping at any interface of the faucet. Solution: tighten it slightly with tools at the interface or after 
wrapping the raw material belt at the thread.
Is there water dripping between shower head and hand shower?
Solution: the right water separator end of the thermostatic faucet is not closed properly. Try to close it to solve this 

problem.

Tip: constant temperature shower is the perfect match with electric water heater and air energy water heater.

After-Sale Service

If you have any issues with the product, please feel free to contact us online or by phone for customer service.
      Phone No.: (909) 430-1666
      Service E-mail: [email protected]

 

www.hernest.com

5

Summary of Contents for H200166

Page 1: ...t is missing or damaged please contact us Do not disassemble the main body as it has been installed commissioned correctly precisely before leaving the factory Shut off the main water supply before the installation Do flush the water supply lines to remove any dirt and debris before installation IMPORTANT Make sure to connect the hot cold inlet pipe correctly If standing in front usually the hot wa...

Page 2: ...ter inlet temperature 55 85 Safety setting button 38 Application standard ASME A112 18 1 2005 CSA B125 1 05 EN1111 and QB2806 2017 Installation Instruction Part List NO Description Qty 1 1 1 1 1 1 1 1 Main body Accessories Straight pipe Shower hose Hand shower Fixed holder Shower head Installation manual 8 7 6 5 4 3 2 1 ...

Page 3: ...e of hot and cold water inlet pipe 59 150mm 2 Install the fixed holder according to actual dimensions Installation Steps 3 3 Assemble and connect the parts in the sequence above 4 Test the product when finishing the installation 130 170mm 5 1 6 7 900 1000mm 35 4 39 4 ...

Page 4: ...mixer temperature above 40 but still no hot water a The direction of cold and hot water supply pipes is opposite to thermostatic mixer Solution change the direction of cold and hot water supply pipes to ensure to follow the principle of left hot right cold b Residual cold water in hot water channel Solution put away residual cold water before use c There is no cold water entering the valve body du...

Page 5: ...he water temperature is fluctuated The main reason is that the water heater sets a default value to meet its own requirements so the water flow and temperature are not enough Solution adjust the default value of the gas water heater factory setting to the conditions required by the thermo static mixer water temperature can be used The electric water heater with the outlet water temperature of the th...

Reviews: