hernest H200166 User Manual Download Page 4

This product is the right hand wheel to control the temperature, the left hand wheel to switch the modes and change 
water flow.

       

The right hand wheel scale is aligned at (38±1) 

 (see the above picture). Rotate clockwise to increase the 

       temperature; rotate counterclockwise to decrease the temperature.

       

The right hand wheel scale is closed when it is aligned (see the above picture). Rotate clockwise, bathtub faucet is 

       vertical to main body,the water from bathtub rotates the swimming mouth 90

 clock wise,the water from hand 

       shower rotate counterclockwise, shower head will be running water.

No hot water

1) Set the thermostatic mixer temperature above 40 

, but still no hot water

a. The direction of cold and hot water supply pipes is opposite to thermostatic mixer. 
Solution: change the direction of cold and hot water supply pipes to ensure to follow the principle of left hot right 

cold.

b. Residual cold water in hot water channel.
Solution: put away residual cold water before use.
c. There is no cold water entering the valve body due to the water supply pipeline being stopped or the cold water 

inlet being blocked.

Solution: clean the filter at the inlet to ensure the supply of cold water.
d. The hot water inlet is blocked, or there is no hot water supply source meeting the use conditions.
Solution: clean the filter at the inlet to ensure that the hot water supply meets the constant temperature use condi

-

tions.

Usage Instruction

Trouble Shooting

4

Summary of Contents for H200166

Page 1: ...t is missing or damaged please contact us Do not disassemble the main body as it has been installed commissioned correctly precisely before leaving the factory Shut off the main water supply before the installation Do flush the water supply lines to remove any dirt and debris before installation IMPORTANT Make sure to connect the hot cold inlet pipe correctly If standing in front usually the hot wa...

Page 2: ...ter inlet temperature 55 85 Safety setting button 38 Application standard ASME A112 18 1 2005 CSA B125 1 05 EN1111 and QB2806 2017 Installation Instruction Part List NO Description Qty 1 1 1 1 1 1 1 1 Main body Accessories Straight pipe Shower hose Hand shower Fixed holder Shower head Installation manual 8 7 6 5 4 3 2 1 ...

Page 3: ...e of hot and cold water inlet pipe 59 150mm 2 Install the fixed holder according to actual dimensions Installation Steps 3 3 Assemble and connect the parts in the sequence above 4 Test the product when finishing the installation 130 170mm 5 1 6 7 900 1000mm 35 4 39 4 ...

Page 4: ...mixer temperature above 40 but still no hot water a The direction of cold and hot water supply pipes is opposite to thermostatic mixer Solution change the direction of cold and hot water supply pipes to ensure to follow the principle of left hot right cold b Residual cold water in hot water channel Solution put away residual cold water before use c There is no cold water entering the valve body du...

Page 5: ...he water temperature is fluctuated The main reason is that the water heater sets a default value to meet its own requirements so the water flow and temperature are not enough Solution adjust the default value of the gas water heater factory setting to the conditions required by the thermo static mixer water temperature can be used The electric water heater with the outlet water temperature of the th...

Reviews: