Protocol description ASCII, SECS/HSMS
Customer manual
Version 1.2
LFM LP Reader
15.01.2019
Page 78 of 119
HERMOS AG
Gartenstrasse 19
Tel. +49(9279) 991-0
D-95490 Mistelgau
Fax. +49(9279) 991-100
data element ECV parameters 0 - 99
Head attribute definitions
:
"HeadStatus" Current state
"IDLE" ...
Reader in REST mode
"BUSY" ...
reader is busy
"NOOP" ...
Not in operation
"HeadID"
corresponds to the 2-digit target ID of the first antenna port
„01“
Where used S18F2, S18F3
ATTRVAL
Format: A[max2]
State request value
OpStatus
Operating status,
maintenance
or rest mode
"OP" ... operating status
"MT" ... maintenance status
LEDStatus
LED-status
"Off" ...
switch off the LED
"On" ...
switch on the LED
"Flash" ...
switch the LED to flashing mode with 1Hz
LedNo
LedNo LED-number, 1Byte
"1"
externe LED of the port
"2" red LED TEST
"3" blue LED TEST
"4" green LED TEST
"5" red LED TUNING
"6" blue LED TUNING
"7" green LED TUNING
"8" red LED STATUS
"9" blue LED STATUS
"A" green LED STATUS
Timeout
Timeout duration, Units seconds
„00“: permanently
„01“ to „FF“:
Timeout from 1 to 255 s. After the timeout, the LED goes off.
Where used
S18F13