Protocol description ASCII, SECS/HSMS
Customer manual
Version 1.2
LFM LP Reader
15.01.2019
Page 113 of 119
HERMOS AG
Gartenstrasse 19
Tel. +49(9279) 991-0
D-95490 Mistelgau
Fax. +49(9279) 991-100
Error codes
SSACK Name
Description
Cause
Corrective action
NO
Normal
operation
Indicates the success of
the requested operation
no
EE
Execute
Error
Transponder data and read
ID sequence cannot be
read
Reader processes
previous read or write
request
Please wait until previous
query is finished
Transponder has no
or too few valid
ASCII characters in the
MID area
Program transponder with
valid ASCII characters in
the MID area
Parameters for MID range
do not match the
transponder data
Adjust reader parameter
for MID area according to
transponder data area
for MID
Wrong reader mode
(MANT / OP) for functional
operation
Switch to proper mode
(MANT to write MID)
CE
Communication
Error
Syntax error with message
or message format
or wrong value
List format, list set
or data type is wrong
Check SECS message
syntax
Data sent with a command
is incorrect
Check command syntax
and data
Send parameter is not
implemented or out of
range
Check parameter syntax
and value